§ 3.05 — Amendments to the International Residential Code, 2021 edition
Code of Ordinances of the City of Allen, Texas (Codified through Ordinance No. 4212-2-26, adopted February 10, 2026 (Supp. No. 23)) · Allen Land Development Code § 3.05
Corpus is an independent public-information project, not the official City of Allen website. Stable reference: corpuslaw.us/code/73143d9e-6f37-4056-a7db-10422acea0ea
Sec. 3.05. - Amendments to the International Residential Code, 2021 edition.
The following amendments to the International Residential Code, 2021 edition, as adopted pursuant to section 3.01, are hereby adopted: 1. Section R102.4 is amended to read as follows: Section R102.4 Referenced codes and standards. The codes, when specifically adopted, and standards referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference and as further regulated in Sections R102.4.1 and R102.4.2. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the amendments as well. Any reference made to NFPA 70, or the ICC Electrical Code shall mean the Electrical Code as adopted. 2. Section R103, and R103.1 are amended to insert the Department Name as follows: R103.1 Creation of enforcement agency. The City of Allen Building Inspection Department is hereby created and the official in charge thereof shall be known as the Building Official. 3. Section R104.10.1 is deleted. 4. Section R105.2 is amended by amending the text under the subtitle "Building" to read as follows: R105.2. Work exempt from permit. Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of this jurisdiction. Permits shall not be required for the following: Building: 1. Water tanks supported directly upon grade if the capacity does not exceed 5,000 gallons (18,925 L) and the ratio of height to diameter or width does not exceed 2 to 1. 2. Sidewalks and driveways and other flat work not more than 30 inches (762 mm) above adjacent grade, and not over any basement or story below and which are not part of an accessible route or exit discharge and the placement and/or location of concrete does not violate other city requirements. 3. Decks less than 200 square feet and not more than 30 inches above grade at any point. (IRC) 4. Window awnings supported by an exterior wall of Group R-3, as applicable in Section 101.2, and Group U occupancies. (IRC) 5. One-story detached accessory structures used as tool and/or storage sheds, playhouses and similar uses provided the floor area does not exceed 120 square feet, or the height does not exceed 8 feet and the placement of the structure does not violate any other city requirements such as but not limited to placement of any structure in the (PDE) Private Drainage Easement. (IRC) 6. Poles installed on a parcel where the primary use is a single-family dwelling, two family dwelling or townhome provided the installation does not exceed the height requirements for the residential zoning district where located as specified in the ALDC. (IRC) 7. Residential swimming or wading pools that are temporary in nature and less than 24 inches in depth and do not require nor are provided with mechanical circulation or heating equipment of any kind. (IRC) 5. Section R105.3.1.1 is deleted. 6. Section R106.1.4 is deleted. 7. Section R108 is amended by adding Section R108.7 to read as follows: R108.7 Re-inspection fee. A fee as established by city council resolution may be charged when: 1. The inspection called for is not ready when the inspector arrives; 2. No building address or permit card is clearly posted; 3. Approved plans are not on the job site and available to the inspector at time of inspection; 4. The building is locked or work otherwise is not available for inspection when called; 5. The job site is red tagged twice consecutively for the same item; 6. The original red tag has been removed from the job site; 7. Violations exist on the property including failure to maintain erosion control, trash control or tree protection; and 8. Any re-inspection fees assessed shall be paid before additional inspections are conducted on that job site. 8. Section R110 (inclusive of Sections R110.1 through R110.5) is deleted in its entirety. 9. Section R112 is amended in its entirety to read as follows: Section R112 MEANS OF APPEAL R112.1 Application for appeal. Any person shall have the right to appeal a decision of the building official to the Board of Adjustment as provided in Section 2.02 of the Allen Land Development Code. 10. Section R202 is amended by amending the definition of "Townhouse" to read as follows: TOWNHOUSE. A single-family dwelling unit constructed in a group of three or more attached units separated by property lines in which each unit extends from foundation to roof and with a yard or public way on at least two sides. 11. Table R301.2(1) is amended to read as follows: TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND SNOW LOAD | WIND DESIGN | SEISMIC DESIGN CATEGORYf SPEEDd (mph) | Topographic Effectsk | Special Wind Regionl | Windborne Debris Zonem 5 lb/ft 2 | 115 (3 sec.-gust)/76 fastest mile | No | No | No | A SUBJECT TO DAMAGE FROM Weatheringa | Frost line depthb | Termitec Moderate | 6" | Very Heavy WINTER DESIGN TEMPe | ICE BARRIER UNDERLAYMENT REQUIREDh | FLOOD HAZARDSg | AIR FREEZING INDEXi | MEAN ANNUAL TEMPj 22°F | No | Local Code | 150 | 64.9°F 12. Section R302.1 is amended by amending paragraph 4, and adding a new paragraph 6 under "Exceptions" to read as follows: Exceptions: 4. Detached garages accessory to a dwelling located within 5 feet of a lot line may have roof projections not exceeding 12 inches. 6. Open metal carport structures may be constructed within three (3) feet of the property line without fire-resistive or opening protection when the location of such is approved as required within adopted ordinances. 13. Section R302.3 is amended by adding Exception 3 to read as follows: 3. Two-family dwelling units that are also divided by a property line through the structure shall be separated as required for townhouses. 14. Section R302.5.1 is amended to read as follows: R302.5.1 Opening protection. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 1 3/8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 1 3/8 inches (35 mm) thick, or 20-minute fire rated doors. 15. Section 303.3 is amended by amending the paragraph titled "Exception" to read as follows: Exception: The glazed areas shall not be required where artificial light and a local exhaust system are provided. The minimum local exhaust rates shall be determined in accordance with Section M1505. Exhaust air from the space shall be exhausted directly to the outdoors. Spaces containing only a water closet or water closet and a lavatory may be ventilated with an approved mechanical recirculating fan or similar device designed to remove odors from the air. 16. Section R313.2 and its subsections are deleted. 17. Section R315.2.2 is amended by amending paragraph 2 under "Exceptions" to read as follows: 2. Installation, alteration, or repairs of electrically powered mechanical systems, or plumbing appliances. 18. Section R322 is deleted. 19. Section R401.2 is amended by adding the following sentence at the end of the section: Every foundation and/or footing, or any size addition to an existing post-tension foundation, regulated by this code shall be designed and sealed by a Texas-registered engineer. 20. Section R602.6.1 is amended to read as follows: R602.6.1 Drilling and notching of top plate. When piping or ductwork is placed in or partly in an exterior wall or interior load-bearing wall, necessitating cutting, drilling or notching of the top plate by more than 50 percent of its width, a galvanized metal tie not less than 0.054 inch thick (1.37 mm) (16 Ga) and 5 inches (127 mm) wide shall be fastened across and to the plate at each side of the opening with not less than eight 10d (0.148-inch diameter) having a minimum length of 1½ inches (38 mm) tie must extend a minimum of 6 inches past the opening. Fasteners will be offset to prevent splitting of the top plate material. The metal tie must extend a minimum of 6 inches past the opening. See figure R602.6.1. ("Exception" remains unchanged) 21. Figure R602.6(1) is amended to appear as follows: [image omitted; see the official code] 22. Section R703.8.4.1 is amended by adding Section 703.8.4.1.2 to read as follows: R703.8.4.1.2 Veneer Ties for Wall Studs. In stud framed exterior walls, all ties shall be anchored to studs as follows: 1. When studs are 16 inches (407 mm) O.C., stud ties shall be spaced no further apart than 24 inches (737 mm) vertically starting approximately 12 inches (381 mm) from the foundation; or 2. When ties are placed on studs 24 inches (610 mm) O.C., stud ties shall be spaced no further apart than 16 inches (483 mm) vertically starting approximately 8 inches (254 mm) from the foundation. 23. Section R902.1 is amended by amending the first paragraph to read as follows: R902.1 Roofing covering materials. Roofs shall be covered with materials set forth in Sections R904 and R905. Class A, B, or C roofing shall be installed. Classes A, B, and C roofing required by this section to be listed shall be tested in accordance with UIL 790, or ASTM E 108. 24. Chapter 11 [RE] Energy Efficiency is deleted in its entirety. 25. Section M1305.1.2 is amended to read as follows: M1305.1.2 Appliances in attics. Attics containing appliances shall be provided … (intervening text unchanged) sides of the appliance where access is required. The clear access opening dimensions shall be a minimum of 20 inches by 30 inches (508 mm by 762 mm), or larger and large enough to allow removal of the largest appliance. A walkway to an appliance shall be ½-inch plywood or 5/8-inch oriented strand board. As a minimum, access to the attic space shall be provided by one of the following: 1. A permanent stair; 2. A pull-down stair with a minimum 300 lb. (136kg) capacity; and 3. An access door from an upper floor level. Exceptions: (unchanged) 26. Section M1401.4 is amended to read as follows: M1401.4 Exterior installations. Equipment and appliances installed outdoors shall be listed and labeled for outdoor installation. No a/c condensers shall be located inside yards less than 7 feet, unless approved by the Building Official. (remaining text unchanged) 27. Section M1411.3 is amended to read as follows: M1411.3 Condensate disposal. Condensate from all cooling coils or evaporators shall be conveyed from the drain pan outlet to a sanitary sewer through a trap, by means of a direct or indirect drain. (remaining text unchanged) 28. Section M1411.3.1 is amended by adding Items 3, and 4 to read as follows: 3. An auxiliary drain pan (intervening text unchanged) with item 1 of this section. A water level detection/shut off device may be installed only with prior approval of the building official. 4. A water level detection device … (intervening text unchanged) overflow rim of such pan. A water level detection/shut off device may be installed with prior approval of the building official. 29. Section M1411.3.1.1 is amended to read as follows: M1411.3.1.1 Water-level monitoring devices. On down-flow units … (bulk of text unchanged) installed in the drain line. A water level detection device may be installed only with prior approval of the building official. 30. Section M1503.6 Makeup Air Required is amended to read as follows: M1503.6 Makeup air required. Where one or more gas, liquid or solid fuel-burning appliance that is neither direct vent nor uses a mechanical draft venting system is located within a dwelling unit's air barrier, each exhaust system capable of exhausting in excess of 400 cubic feet per minute (0.19 m3/s) shall be mechanically or passively provided with makeup air at a rate approximately equal to the difference between the exhaust air rate and 400 cubic feet per minute. Such makeup air systems shall be equipped with no fewer than one damper complying with Section M1503.6.2. Exception: Make up air is not required for exhaust systems installed for the exclusive purpose of space cooling and intended to be operated only when windows or other air inlets are open. Where all appliances in the house are of sealed combustion, power-vent, unvented, or electric, the exhaust hood system shall be permitted to exhaust up to 600 cubic feet per minute (0.28 m3/s) without providing makeup air Exhaust hood systems capable of exhausting in excess of 600 cubic feet per minute (0.28 m3/s) shall be provided with a makeup air at a rate of approximately equal to the difference between the exhaust air rate and 600 cubic feet per minute. 31. Section M1601.4.4 is amended to read as follows: M1601.4.4 Support. Metal ducts listed in accordance with UL 181 shall be supported in accordance with manufacturer's installation instructions or other approved means. Flexible ducts shall be supported by 1-inch wide 18-gauge solid metal straps with 6" metal saddles at intervals not exceeding 10 feet or in accordance with the manufacturer's installation instructions. 32. Section M2005.2 is amended to read as follows: M2005.2 Prohibited locations. Fuel-fired water heaters shall not be installed in a room used as a storage closet. Water heaters located in a bedroom or bathroom shall be installed in a sealed enclosure so that combustion air will not be taken from the living space. Access to such enclosure may be from the bedroom or bathroom when through a solid door, weather-stripped in accordance with the exterior door air leakage requirements of the International Energy Conservation Code and equipped with an approved self-closing device. Installation of direct-vent water heaters within an enclosure is not required. No tank type water heaters shall be permitted to be installed in New Residential attics. Tank less type of water heater(s) shall be approved for attic installation and shall require a pan and drain the T&P line directly to the outdoor or approved location. 33. Section G2404.1 (301.1) is amended by adding the following sentence to the end of the section: All gas meters shall be located on the structure. 34. Section G2408.3 (305.5) is deleted. 35. Section G2415.2 (404.2) is amended by adding a second paragraph to read as follows: Both ends of each section of medium pressure gas piping shall identify its operating gas pressure with an approved tag. The tags are to be composed of aluminum or stainless steel and the following wording shall be stamped into the tag: "WARNING: 1/2 to 5 psi gas pressure - Do Not Remove" 36. Section 2415.12 (404.12) is amended to read as follows: G2415.12 (404.12) Minimum burial depth. Underground piping systems shall be installed a minimum depth of 18 inches (457 mm) below grade. 37. Section G2415.12.1 (404.12.1) is deleted. 38. Section G2417.1 (406.1) is amended to read as follows: G2417.1 (406.1) General. Prior to acceptance and initial operation, all piping installations shall be inspected, and pressure tested to determine that the materials, design, fabrication, and installation practices comply with the requirements of this Code. The permit holder shall make the applicable tests prescribed in Sections 2417.1.1 through 2417.1.5 to determine compliance with the provisions of this Code. The permit holder shall give reasonable advance notice to the building official when the piping system is ready for testing. The equipment, material, power and labor necessary for the inspections and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. The pressure test will require a diaphragm gauge that has been certified annually and the system tested through its entirety and with All stops open. 39. Section G2417.4 is amended to read as follows: G2417.4 (406.4) Test pressure measurement. Test pressure shall be measured with a manometer or with a pressure-measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. 40. Section G2417.4.1 is amended to read as follows: G2417.4.1 (406.4.1) Test pressure. The test pressure to be used shall be not less than 3 psig (20 kPa gauge), or at the discretion of the building official, the piping and valves may be tested at a pressure of at least six (6) inches (152 mm) of mercury, measured with a manometer or slope gauge. For tests requiring a pressure of 3 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three-and one-half inches (3 1/2"), a set hand, 1/10-pound incrementation and pressure range not to exceed 6 psi for test requiring a pressure of 3 psig. For tests requiring a pressure of 10 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three and one-half inches (3½"), a set hand, a minimum of 2/10-pound incrimination and a pressure range not to exceed 20 psi. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa) (1/2 psa) and less than 200 inches of water column pressure (52.2 kPa) (7.5 psi), the test pressure shall not be less than ten (10) pounds per square inch (69.6 kPa). For piping carrying gas at a pressure that exceeds 200 inches of water column (52.2 kPa) (7.5 psi), the test pressure shall be not less than one and one-half times the proposed maximum working pressure. Diaphragm gauges used for testing must display a current calibration and be in good working condition. The appropriate test must be applied to the diaphragm gauge used for testing. 41. Section G2417.4.2 is amended to read as follows: G2417.4.2 (406.4.2) Test duration. Test duration shall be held for a length of time satisfactory to the building official, but in no case for less than fifteen (15) minutes. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa), the test duration shall be held for a length of time satisfactory to the building official, but in no case for less than thirty (30) minutes. The test shall be through the entire system with All stops open. 42. Section G2420.1 (409.1) is amended by adding Section G2420.1.4 to read as follows: G2420.1.4 (409.1.4) Valves in CSST installations. Shutoff valves installed with corrugated stainless steel (CSST) piping systems shall be supported with an approved termination fitting, or equivalent support, suitable for the size of the valves, of adequate strength and quality, and located at intervals so as to prevent or damp out excessive vibration but in no case greater than 12-inches from the center of the valve. Supports shall be installed so as not to interfere with the free expansion and contraction of the system's piping, fittings, and valves between anchors. All valves and supports shall be designed and installed so they will not be disengaged by movement of the supporting piping. 43. Section G2420.5.1 (409.5.1) is amended to read as follows: G2420.5.1 (409.5.1) Located within the same room. The shutoff valve (Intervening text unchanged) in accordance with the appliance manufacturer's instructions. A secondary shutoff valve must be installed within 3 feet (914 mm) of the firebox if appliance shutoff is located in the firebox. 44. Section G2421.1 (410.1) is amended to read as follows: G2421.1 (410.1) Pressure regulators. A line pressure regulator shall be... (intervening text unchanged) approved for outdoor installation. Access to regulators shall comply with requirements for access to appliances as specified in Section M1305. Exception: A passageway or level service space is not required when the regulator is capable of being serviced and removed through the required attic opening. 45. Section G2445.2 (621.2) is amended by adding a paragraph titled "Exception" to read as follows: G2445.2 (621.2) Prohibited use. One or more unvented room heaters shall not be used as the sole source of comfort heating in a dwelling unit. Exception: Existing approved unvented heaters may continue to be used in dwelling units, in accordance with the code provisions in effect when installed, when approved by the building official unless an unsafe condition is determined to exist as described in International Fuel Gas Code Section 108.7 of the Fuel Gas Code. 46. Section G2448.1.1 (624.1.1) is amended to read as follows: G2448.1.1 (624.1.1) Installation requirements. The requirements for water heaters relative to access, sizing, relief valves, drain pans and scald protection shall be in accordance with this code. 47. Section P2602.1 is amended by amending the paragraph titled "Exception" to read as follows: Exception: Sanitary drainage systems that were installed with a septic tank or septic system, upon failure or need of repair must be connected to the City Sanitary Sewer System. 48. Section P2603.3 is amended to read as follows: P2603.3 Protection against corrosion. Metallic piping, except for cast iron, ductile iron and galvanized steel, shall not be placed in direct contact with steel framing members, concrete or cinder walls and floors or other masonry. Metallic piping shall not be placed in direct contact with corrosive soil. Where sheathing is used to prevent direct contact, the sheathing shall have a thickness of not less than 0.008 inch (8 mil) (0.203 mm) and the sheathing shall be made of approved material. Where sheathing protects piping that penetrates concrete or masonry walls or floors, the sheathing shall be installed in a manner that allows movement of the piping within the sheathing. 49. Section P2603.5.1 is amended to read as follows: P2603.5.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be a minimum of 12 inches (304 mm) below finished grade at the point of septic tank connection. Building sewers shall be a minimum of 12 inches (304 mm) below grade. 50. Section P2604.2 is amended by adding Section P2604.2.1 to read as follows: P2604.2.1 Plastic sewer and DWV piping installation. Plastic sewer and DWV piping installed underground shall be installed in accordance with the manufacturer's installation instructions. Trench width shall be controlled to not exceed the outside the pipe diameter plus 16 inches or in a trench which has a controlled width equal to the nominal diameter of the piping multiplied by 1.25 plus 12 inches. The piping shall be bedded in 4 inches of granular fill and then backfilled compacting the side fill in 6-inch layers on each side of the piping. The compaction shall be to minimum of 85 percent standard proctor density and extend to a minimum of 6 inches above the top of the pipe. 51. Section P2718.1 is amended by adding new Section P2718.1.1 to read as follows: Section P2718.1.1 Pan required. All clothes washing machines on a second floor or above shall have a pan. The pan shall be tested with a water test during construction and exit the exterior of the structure to the outside. 52. Section P2801.5 is amended to read as follows: Section P2801.5 Prohibited locations. Water heaters shall be located in accordance with Chapter 20. No tank type water heaters shall be permitted to be installed in New Residential attics. Tank less water heater(s) may be approved for attic installation and shall require a pan and drain the T&P line directly to the outdoor or approved location. 53. Section P2801.6.1 is amended to read as follows: P2801.6.1 Pan size and drain. The pan shall be not less than 1 1/2 inches (38 mm) in depth and shall be of sufficient size and shape to receive all dripping or condensate from the tank or water heater. The pan shall be drained by an indirect waste pipe having a diameter of not less than ¾ inch (19 mm). Piping for safety pan drains shall be of those materials listed in Table 605.4. Multiple pan drains may terminate to a single discharge piping system when approved by the administrative authority and permitted by the manufacturer's installation instructions and installed with those instructions. 54. Section P2801.7 is amended by adding an "Exception" to read as follows: Exception: Electric Water Heater. 55. Section P2804.6.1 is amended to read as follows: P2804.6.1 Requirements for discharge piping. The discharge piping serving a pressure relief valve, temperature relief valve or combination thereof shall: 1. Not be directly connected to the drainage system; 2. Discharge through an air gap; 3. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap; 4. Serve a single relief device and shall not connect to piping serving any other relief device or equipment; and Exception: Multiple relief devices may be installed to a single T & P discharge piping system when approved by the administrative authority and permitted by the manufacturer's installation instructions and installed with those instructions. 5. Discharge to an indirect waste receptor or to the outdoors. (Remaining text is unchanged) 56. Section P2902.5.3 is amended to read as follows: P2902.5.3 Lawn Irrigation Systems. The potable water supply system to lawn irrigation systems shall be protected against backflow by an atmospheric-type vacuum breaker, a pressure-type vacuum breaker, a double-check assembly or a reduced pressure principle backflow preventer. A valve shall not be installed downstream from an atmospheric vacuum breaker. Where chemicals are introduced into the system, the potable water supply shall be protected against backflow by a reduced pressure principal backflow preventer. All irrigation systems shall have rain and freeze protection installed. 57. Section P3003.9.2 is amended to read in its entirety as follows: P3003.9.2 Solvent cementing. Joint surfaces shall be clean and free from moisture. A purple primer that conforms to ASTM F656 shall be applied. Solvent cement not purple in color and conforming to ASTM D2564, CSA B137.3, CSA B181.2, or CSA B182.1 shall be applied to all joint surfaces. The joint shall be made while the cement is wet and shall be in accordance with ASTM D2855. Solvent cement joints shall be permitted above or below ground. 58. Section P3111 including all subsections, is deleted in its entirety. 59. Section P3112.2 is amended in its entirety to read as follows: P3112.2 Installation. Traps for island sinks and similar equipment shall be roughed in above the floor and may be vented by extending the vent as high as possible, but not less than the drainboard height and then returning it downward and connecting it to the horizontal sink drain immediately downstream from the vertical fixture drain. The return vent shall be connected to the horizontal drain through a wye-branch fitting and shall, in addition, be provided with a foot vent taken off the vertical fixture vent by means of a wye-branch immediately below the floor and extending to the nearest partition and then through the roof to the open air or may be connected to other vents at a point not less than six (6) inches (152 mm) above the flood level rim of the fixtures served. Drainage fittings shall be used on all parts of the vent below the floor level and a minimum slope of one-quarter (1/4) inch per foot (20.9 mm/m) back to the drain shall be maintained. The return bend used under the drainboard shall be a one (1) piece fitting or an assembly of a forty-five (45) degree (0.79 radius), a ninety (90) degree (1.6 radius) and a forty-five (45) degree (0.79 radius) elbow in the order named. Pipe sizing shall be as elsewhere required in this Code. The island sink drain, upstream of the return vent, shall serve no other fixtures. An accessible cleanout shall be installed in the vertical portion of the foot vent.
(Ord. No. 3919-6-22, § 1, 6-14-2022)
Ask a question about Allen law
Corpus searches the Allen sections it holds and shows the ones that match, with their citations. Free, no sign-in.