§ 3.06 — Amendments to International Mechanical Code, 2021 edition
Code of Ordinances of the City of Allen, Texas (Codified through Ordinance No. 4212-2-26, adopted February 10, 2026 (Supp. No. 23)) · Allen Land Development Code § 3.06
Corpus is an independent public-information project, not the official City of Allen website. Stable reference: corpuslaw.us/code/8dfd8a25-dfdd-4bc1-82c5-30c217998227
Sec. 3.06. - Amendments to International Mechanical Code, 2021 edition.
The following amendments to the International Mechanical Code, 2021 edition, as adopted pursuant to section 3.01, are hereby adopted: 1. Section 102.8 is amended to read as follows: 102.8 Referenced codes and standards. The codes and standards referenced herein shall be those that are listed in Chapter 15 and such codes, when specifically adopted, and standards shall be considered part of the requirements of this code to the prescribed extent of each such reference. Where differences occur between provisions of this code and the referenced standards, the provisions of this code shall apply. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the amendments as well. Any reference to NFPA 70 or the ICC Electrical Code shall mean the Electrical Code as adopted. 2. Sections 106.5.2, and 106.5.3 are amended to read as follows: 106.5.2 Fee schedule. Fees for the issuance of permits and performance of inspections as required by this code shall be as established from time to time by resolution of the City Council and set forth in the City's Fee Schedule 106.5.3 Fee refunds. The building official shall establish a policy for authorizing the refunding of fees. 3. Section 306.3 is amended to read as follows: 306.3 Appliances in attics. Attics containing appliances shall be provided (intervening language unchanged) … side of the appliance. The clear access opening dimensions shall be a minimum of 20 inches by 30 inches (508 mm by 762 mm), or larger where such dimensions are not large enough to allow removal of the largest appliance. A walkway to an appliance shall have continuous solid flooring with a minimum thickness of ½-inch plywood or 5/8-inch oriented strand board, and shall be placed over a load bearing wall or with engineered approval. At a minimum, for access to the attic space, provide one of the following: 1. A permanent stair; 2. A pull-down stair with a minimum 300 lbs. (136 kg) capacity; and 3. An access door from an upper floor level. 4. Section 306.5.1 is amended to read as follows: 306.5.1 Sloped roofs. Where appliances, equipment, fans or other components that require service are installed on roofs having a slope of 3 unit's vertical in 12 units horizontal or greater and having an edge more than 30 inches (762 mm) above grade at such edge, a catwalk at least 16 inches in width with substantial cleats spaced not more than 16 inches apart shall be provided from the roof access to a level platform at the appliance. The level platform shall be provided on each side of the appliance to which access is required for service, repair or maintenance. The platform shall be not less than 30 inches (762 mm) in any dimension and shall be provided with guards. The guards shall extend not less than 42 inches (1067 mm) above the platform, shall be constructed so as to prevent the passage of a 21-inch-diameter (533 mm) sphere and shall comply with the loading requirements for guards specified in the International Building Code. 5. Section 306 is amended by adding Section 306.6 to read as follows: 306.6 Water heaters above ground or floor. When the mezzanine or platform in which a water heater is installed is more than eight (8) feet (2438 mm) above the ground or floor level, it shall be made accessible by a stairway or permanent ladder fastened to the building. Exception: A maximum 10-gallon water heater (or larger with approval) is capable of being accessed through a lay-in ceiling and a water heater is installed is not more than ten (10) feet (3048 mm) above the ground or floor level and may be reached with a portable ladder. 306.6.1 Inadequate lighting at location. Whenever the mezzanine or platform is not adequately lighted or access to a receptacle outlet is not obtainable from the main level, lighting and a receptacle outlet shall be provided in accordance with Section 306.3.1. 6. Section 307.2.3 is amended by amending numbered paragraph 2 to read as follows: 2. A separate overflow drain line shall be connected to the drain pan provided with the equipment. Such overflow drain shall discharge to a conspicuous point of disposal to alert occupants in the event of a stoppage of the primary drain. The overflow drain line shall connect to the drain pan at a higher level than the primary drain connection. However, the conspicuous point shall not create a hazard such as dripping over a walking surface or other areas so as to create a nuisance. 7. Section 403.2.1 is amended by adding paragraph 5 to read as follows: 5. Toilet rooms within private dwellings that contain only a water closet, lavatory or combination thereof may be ventilated with an approved mechanical recirculating fan or similar device designed to remove odors from the air. 8. Section 505.1 is amended to read as follows: 505.1 General. Domestic cooking exhaust equipment shall comply with the requirements of this section. All domestic cooking exhaust equipment ventilation shall be made vertical through the roof and shall not be permitted horizontal. 9. Section 506.1 is amended to read as follows: 506.1 General. Commercial kitchen hood ventilation ducts and exhaust equipment shall comply with the requirements of this section. All commercial cooking exhaust equipment ventilation shall be made vertical through the roof and shall not be permitted horizontal. Type I, and Type II hoods. 10. Section 603.6.1.1 is amended to read as follows: 603.6.1.1 Duct length. Flexible air ducts shall be a maximum of 5' (feet) and are required to have 1" (inch) solid metal straps and 6" (inch) metal saddles. 11. Section 607.5.1 is amended to read as follows: 607.5.1 Fire Walls. Ducts and air transfer openings permitted in fire walls in accordance with Section 706.11 of the International Building Code shall be protected with listed fire dampers installed in accordance with their listing. For hazardous exhaust systems see Section 510.1-510.9 IMC.
(Ord. No. 3919-6-22, § 1, 6-14-2022)
Ask a question about Allen law
Corpus searches the Allen sections it holds and shows the ones that match, with their citations. Free, no sign-in.