Section 24-59.3.2.1 - STREETS AND CLOSED STORM SEWER SYSTEMS

Streets may be used for stormwater drainage only if the calculated stormwater flow does not exceed ten (10) feet per second. Streets and alleys shall be designed on the basis of a ten (10) year frequency storm event. Storm sewer inlets shall be built along paved streets at such intervals that the depth of flow, based upon the 10-year storm, does not exceed the top of curb. By pass flow is allowed and shall not exceed twenty-five (25) percent of the original discharge. Valley gutters shall be placed when surface drainage crosses any local street or in instances when the change in elevation between curbs returns exceeds six (6) inches. Inlets shall be located as necessary to remove the flow based on a ten (10) year storm. At any intersection, only one (1) street shall be crossed with surface drainage; and preferably this street shall be the lower classified street. When an alley intersects a street, inlets shall be placed in the alley whenever flow down that alley would cause the capacity of the intersecting street to be exceeded. Where streets are not capable of carrying stormwaters as outlined above, drainage facilities as required by these standards shall be provided. Where closed storm sewer systems are utilized the excess discharge shall be picked up at the point where the street can no longer handle the runoff flowing curb full. Closed storm sewer pipe size and grade shall be designed based on the following criteria: a. Minimum pipe size shall be twenty-four (24) inches in diameter. When circumstances do not allow for a twenty-four (24) inch diameter, the City Engineer may approve an alternate size. b. Minimum grade shall be such that the minimum flow velocities are not less than three (3) feet per second with the pipe flowing full under the design conditions. c. Allowable "n" values for design shall be as specified in the Stormwater Management Guidance Manual. d. Under normal conditions, pipes shall be designed assuming full flow conditions. e. Where conditions or design cause a pipe to flow under pressure, the hydraulic grade line shall be calculated and plotted in profile. In no case shall the hydraulic grade line be closer than one (1) foot to finished grade unless specifically authorized by the City Engineer. f. Pipe for storm drains shall be reinforced concrete pipe (RCP) in sizes as shown on the approved plans. All RCP shall be minimum Class III. All Class III RCPs shall have a minimum cover of not less than one (1) foot over the top of the pipe. Where added strength of pipe is needed for traffic loads over minimum cover or for excessive height of backfill, concrete pipe shall be ASTM C14 Extra Strength or ASTM C76, Class IV or Class V. g. City Engineer may approve alternate pipe materials (HDPE, FIBER GLASS, CMP, etc.) within the private easement, positive overflow area and within the Right-of-Way (ROW).

Ask a question about Laredo law

Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.