§ 24-59.3.2.5.1 — ALLOWABLE DISCHARGE - (PRE/POST ANALYSIS FOR RETENTION/DETENTION FACILITIES)

Code of Ordinances, City of Laredo, Texas (Supp. No. 23, Update 3: codified through Ordinance No. 2026-O-92, adopted May 4, 2026) · Laredo Land Development Code § 24-59.3.2.5.1

Corpus is an independent public-information project, not the official City of Laredo website. Stable reference: corpuslaw.us/code/968bab59-facc-477f-ab72-a5ebd465bb8e

Section 24-59.3.2.5.1 - ALLOWABLE DISCHARGE - (PRE/POST ANALYSIS FOR RETENTION/DETENTION FACILITIES)

The ultimate one hundred (100) year design storm event shall be used in determining the required retention/detention volume for the development site. The discharge rate from the facility shall be such that the pre-development discharge rate from the site is not exceeded in the post-developed condition for the design storm event. The precondition discharge rate shall be calculated assuming the proposed site is in a natural state. Upstream adjacent properties shall be considered at their existing conditions, provided that the downstream receiving stream/channel/detention pond can accept additional stormwater runoff volume without causing flooding as determined by the City Engineer.

Ask a question about Laredo law

Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.