§ 24-59.3.2.5.4 — FREEBOARD AND EMERGENCY SPILLWAY

Code of Ordinances, City of Laredo, Texas (Supp. No. 23, Update 3: codified through Ordinance No. 2026-O-92, adopted May 4, 2026) · Laredo Land Development Code § 24-59.3.2.5.4

Corpus is an independent public-information project, not the official City of Laredo website. Stable reference: corpuslaw.us/code/a36a17c3-192f-4c06-95c3-85ea27f96897

Section 24-59.3.2.5.4 - FREEBOARD AND EMERGENCY SPILLWAY

The top of the embankment shall be a minimum of one (1) foot above the one hundred (100) year maximum design elevation. An emergency spillway, or overflow area, shall be provided above the maximum design elevation to ensure that the State of Texas Dam Safety overflow requirements or the one hundred (100) year frequency event, whichever is more stringent, does not overtop the embankment. If the emergency spillway capacity is to be provided over the embankment, the spillway will be structurally designed to prevent erosion and consequent loss of structural integrity. The spillway or the dam portion of the pond shall be constructed of reinforced concrete or with concrete lining. Alternate materials may be approved by the City Engineer.

Ask a question about Laredo law

Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.