§ 24-59.3.2.5.8 — MAINTENANCE ACCESS REQUIREMENTS
Code of Ordinances, City of Laredo, Texas (Supp. No. 23, Update 3: codified through Ordinance No. 2026-O-92, adopted May 4, 2026) · Laredo Land Development Code § 24-59.3.2.5.8
Corpus is an independent public-information project, not the official City of Laredo website. Stable reference: corpuslaw.us/code/d991ca4b-52a6-48d2-a875-c08044a6ccbe
Section 24-59.3.2.5.8 - MAINTENANCE ACCESS REQUIREMENTS
A minimum fifteen (15) foot wide maintenance area shall be provided to serve the detention facility. The crown (top of berm) shall have a minimum width of ten (10) feet unless used for primary maintenance of the detention facility, in which case it shall have a minimum width of fifteen (15) feet. Access must be provided into detention basins designed for periodic desilting and debris removal. Basins with permanent storage must include dewatering facilities to provide for maintenance.