All roadway culvert crossings shall be designed for a twenty-five (25) year frequency storm event. Crossings located within flood hazard zones shall be designed to ensure compliance with FEMA regulations. The hydraulic capacity of proposed culverts shall be such that headwater depth is at least one (1) foot below the minimum roadway elevation. Proposed bridges shall have a low chord elevation at least one (1) foot above the design stormwater surface elevation. All culverts located or expected to be located under paving and bridges shall be structurally designed for an HS-20 loading. Hydrologic and hydraulic calculations for all crossings must be included in the permit application to ensure compliance with this Code. All culvert and bridge crossing(s) need to have the flood gauge installed by the developer before acceptance by the City.