§ 24-59.3.3.1 — EASEMENTS FOR ENCLOSED STORM SEWERS, POSITIVE OVERFLOW AREAS AND LOT DRAINAGE
Code of Ordinances, City of Laredo, Texas (Supp. No. 23, Update 3: codified through Ordinance No. 2026-O-92, adopted May 4, 2026) · Laredo Land Development Code § 24-59.3.3.1
Corpus is an independent public-information project, not the official City of Laredo website. Stable reference: corpuslaw.us/code/1fc3a359-7066-4625-b0b9-14203d7a01dc
Section 24-59.3.3.1 - EASEMENTS FOR ENCLOSED STORM SEWERS, POSITIVE OVERFLOW AREAS AND LOT DRAINAGE
A grading plan shall be prepared and submitted to the City, which indicates typical lot grading for all lots in the subdivision using typical FHA lot grading types (A, B, and C). See Figure 24-59.3.3.1 - Typical FHA lot grading. [image omitted; see the official code] 24-59.3.3.1 - Typical FHA lot grading All storm sewer conduits to be dedicated to the City shall be located in an easement dedicated to the City of Laredo at the time of final platting of the property. The easement shall be at least fifteen (15) feet wide for storm sewers, or wider if the City Engineer requires it for maintenance or other purposes. Special drainage easements for positive overflows on private property shall be a minimum of ten (10) feet wide, or wider if the City Engineer requires it, for maintenance or other purposes. Accumulated drainage from more than one (1) residential lot (or more than one (1) lot equivalent in the case of staggered or offset lots) shall be contained within a Special Drainage Easement. This easement shall be dedicated to the City at the time of final platting of the property. This shall be a special drainage easement on private property and shall be a minimum of ten (10) feet wide. The easement may be shared with underground utility easements provided those facilities do not impede the calculated runoff. Front to rear lot drainage shall not exceed a maximum slope of five percent (5%). No flow restricting fences, buildings, structures, or other improvements which impede flow shall be placed within these easements. Single front to rear residential lot drainage, or one (1) lot equivalent in the case of staggered, or offset lots do not require Special Drainage Easement. Front to rear lot drainage shall not exceed a maximum slope of five percent (5%). All lots draining and/or receiving runoff will be identified with a plat note. Flow restricting fences or other structures installed between these lots shall be constructed to the specifications of the engineer of record. Said specifications shall be located on the recorded grading plan. Additionally, the homebuilder shall install a twenty (20) feet wide sod strip along entire rear property line of lots draining onto other lots ten (10) feet strip on upgradient lot and ten (10) feet strip on downgradient lot). WARNING AND DISCLAIMER OF LIABILITY The degree of flood protection required by this article is considered reasonable for regulatory purposes and is based on scientific and engineering considerations. Larger floods can and will occur on rare occasions. Flood heights may be increased by manmade or natural causes. This article does not imply that land outside the area of special flood hazards or uses permitted within such areas will be free from flooding or flood damages. This ordinance does not imply that properties shall always be free from flooding or flood damage, surface water stagnation or nonpoint source pollution or that all flood control and water treatment projects to control the quantity and quality of runoff can be constructed effectively. Nothing whatsoever in this ordinance should be construed as or be deemed to create additional duties, on the part of the city, to hold the city liable for any damages incurred in a flood or from adverse water quality, due to drainage runoff. Nothing in this ordinance shall be deemed to waive the city's immunity under state law or reduce the need or necessity for flood insurance.
Ask a question about Laredo law
Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.
