§ 18-401 — Heating furnaces and boilers
Municipal Code of the City of Racine, Wisconsin (Codified through Ordinance No. 0082-26, adopted March 3, 2026. (Supp. No. 108)) · Racine Municipal Code § 18-401
Corpus is an independent public-information project, not the official City of Racine website. Stable reference: corpuslaw.us/code/7ffc53e9-9f41-4c0d-addb-3e9611cb45d3
Sec. 18-401. - Heating furnaces and boilers.
(a) Definitions. The following words, terms and phrases, when used in this section, shall have the meanings ascribed to them in this subsection, except when the context clearly indicates a different meaning: Central furnace means a self-contained flue connected appliance intended primarily to supply heated air through ducts to spaces remote from or adjacent to the appliance location as well as to the space in which it is located. Heating furnaces and boilers means and includes central furnaces, hot water boilers operating at not in excess of 250 degrees Fahrenheit and steam boilers operating at not in excess of 15 pounds gauge pressure. (b) Mounting. (1) Furnaces and boilers fired by combustible fuel shall be mounted on floors of fire-resistive construction with noncombustible flooring and surface finish and with no combustible material against the unit. When solid fuel is used, fire-resistive construction shall extend not less than 18 inches at the front or side where ashes are removed. (2) Furnaces and boilers that are approved specifically for installation on a floor or wall constructed of combustible material may be mounted in accordance with the conditions of such approval. (3) Furnaces and boilers fired by combustible fuel located on the same floor as sleeping quarters shall be isolated by at least a one-hour fire-resistive separation. (c) Clearances. (1) Clearance between the heat producing apparatus supply ducts and combustible materials shall not be less than those recommended for use by National Fire Protection Association Booklet 90B, a copy of which is on file in the office of the chief building inspector. Listed clearances can be reduced through use of protection specified by the National Fire Protection Association Booklet 90B. (2) Heating furnaces and boilers fired by combustible fuel shall not be installed in confined spaces such as alcoves or closets unless they have been approved specifically for such installation and are installed in accordance with the conditions of such approval. Installation clearances for furnaces and boilers in confined spaces shall not be reduced by protection methods. Air for combustion shall be provided for. (3) Minimum clearances from supply ducts, risers, boots and register boxes shall be as recommended by the National Board of Underwriters. (4) Clearances for gas appliances shall be as per current AGA or ASA Standards.
(Code 1973, § 30.36.020)
Ask a question about Racine law
Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.