Sec. 18-405. - Connections to chimneys or vents.
(a) The following appliances shall be required to be flue connected or vented, as provided in this section: (1) Every heat producing appliance burning solid, liquid or gaseous fuel shall be connected to a chimney or vent that is suitable and safe. (2) Gas burning ranges, hot plates, laundry stoves and domestic clothes dryers that are approved specifically for use without a vent may be installed in accordance with the conditions of such approval. (3) Gas burning water heaters with inputs not over 5,000 Btu's per hour, gas refrigerators, counter appliances, room heaters except when installed in sleeping quarters, and other gas burning appliances not provided with flue collars that are approved specifically for unvented use may be installed under the conditions of such approval. Gas burning devices requiring venting, other than central heating devices, shall be vented through an approved vent and such vent shall terminate in the outside air in accordance with the conditions of such approval. (b) Flue pipes and vent connectors. (1) Materials. Flue pipes and vent connectors shall be made of noncombustible material capable of withstanding the flue gas temperatures of the appliances and of 24 gauge minimum thickness to withstand physical damage. The material of vent connectors shall also be resistant to corrosion. (2) Support. Flue pipes and vent connectors shall be securely supported and joints fastened with sheet metal screws or rivets. (3) Pitch. Flue pipes and vent connectors shall maintain a pitch or rise of at least one-quarter inch to the foot (horizontal length) from the appliance to the chimney or vent. (4) Length. Connection to the chimney shall be as direct as possible and in no case shall the horizontal vent exceed 75 percent of the vertical height of the chimney above the flue connection. (5) Size. The flue pipe or vent connector shall not be smaller than: a. The size of the flue collar of the appliance; b. The size recommended by the appliance manufacturer; or c. The size of the outlet of the draft hood that is supplied by the manufacturer of the gas burning appliance. When house-heating gas conversion burners are installed, the flue size shall be that suggested by American Standard Z-21-8-1958, Table 1, page 13. (6) Damper. No manually operated damper shall be placed in such flue or vent connector. (7) Passage through floors or ceilings. No flue pipe or vent connector shall pass through any floor or ceiling. (8) Passage through walls or partitions. Flue pipes of liquid or solid fuel burning appliances shall not pass through walls or partitions constructed of combustible material unless they are guarded at the point of passage by: a. Metal ventilated thimbles not less than 12 inches larger in diameter than the flue pipe or vent connector; b. Metal or burned fire clay thimbles built in brickwork or other approved fireproofing materials extending not less than eight inches beyond all sides of the thimble; or c. In lieu of such protection, all combustible material in the wall or partition shall be cut away from the flue pipe or vent connector a sufficient distance to provide the clearance required from such flue pipe or vent connector. Any material used to close up such opening shall be noncombustible. (9) Openings. Not more than one opening shall be allowed in each chimney flue; other connections may be made by means of an approved junction box. One additional opening for an incinerator may be made provided it does not open into the same section of flue liner.
(Code 1973, § 30.36.060; Ord. No. 7-96, pt. 2, 4-2-96)
Ask a question about Racine law
Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.