§ 18-407 — Air ducts

Municipal Code of the City of Racine, Wisconsin (Codified through Ordinance No. 0082-26, adopted March 3, 2026. (Supp. No. 108)) · Racine Municipal Code § 18-407

Corpus is an independent public-information project, not the official City of Racine website. Stable reference: corpuslaw.us/code/16b8b4ef-c320-42d3-99e4-0c32759e9bf2

Sec. 18-407. - Air ducts.

(a) Warm air supply ducts. (1) All warm air supply registers shall be connected to the furnace or other heating unit by means of fittings and ducts which are continuous and substantially airtight throughout. Warm air supply ducts shall be constructed entirely of metal or other noncombustible material equivalent in structural strength and durability. The minimum thickness of metal used for warm air ducts shall be of the U.S. standard sheet metal gauges shown in the following table: Round ducts— Diameter in inches | Gauge Less than 12 | 30 12 or more | 28 Rectangular ducts— Width in inches | Gauge 14 or less | 28 Over 14 | 26 (2) Joints and seams of such ducts shall be securely fastened. Slip joints shall have a lap of at least one inch and the units shall be securely fastened together. Ducts shall be securely supported by metal hangers, straps, lugs, or brackets. No nails, conduit, wiring or pipe shall penetrate through the duct walls. (3) Single wall ducts when passing through or contained in combustible walls, floors or ceilings shall have 5/16 -inch clearance to combustible construction, and shall be covered with one thickness of asbestos paper weighing not less than 12 pounds per 100 square feet, except that the 5/16 -inch clearance and the asbestos paper may be omitted on ducts from automatically fired forced air furnaces. (4) Ducts located in closets shall be covered with one-quarter-inch approved noncombustible insulation and shall be protected from mechanical injury. (5) Any open space around vertical ducts where such ducts enter walls, floors or ceilings shall be tightly filled with asbestos cement or other approved noncombustible insulating material. (6) Warm air ducts in gravity systems and risers in forced air installation shall be installed so that the same ducts or risers shall not serve both the bathroom and any other room. (7) Warm air supply ducts shall not terminate in any garage area. (b) Cold air return ducts. (1) All cold air return registers shall be connected to the furnace by means of fittings and ducts which are continuous and substantially airtight throughout. (2) Portions of cold air return ducts within three feet of the furnace shall conform to the regulations of subsection (a)(1) of this section for warm air supply ducts. The remaining portions of cold air return ducts may be constructed of metal or other approved material; provided, however, that no material more flammable than one-inch-thick (nominal) wood boards shall be used. (3) Spaces between structural framing members may serve as return ducts provided such spaces are substantially airtight or are made tight with heavy asbestos paper secured to such framing members. When spaces between joists are used for this purpose, such spaces shall be closed with metal, dense composition board, cement-asbestos board, or similar approved rigid material. (4) The interior of combustible return ducts shall be lined with metal at points where there is danger of incandescent particles being dropped through the register, such as directly under floor registers and at the bottom of vertical ducts. (5) Cold air return ducts from bathrooms or garages shall not be permitted. (c) Warm air registers. Where warm air registers are installed in combustible construction, the register box shall be covered with one thickness of asbestos paper weighing not less than 12 pounds per 100 square feet and shall have a clearance of 5/16 -inch from combustible construction, except that the 5/16 -inch clearance to combustible construction may be omitted where an automatically fired forced air furnace is used.

(Code 1973, § 30.36.080)

Ask a question about Racine law

Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.