Sec. 18-403. - Oil burners.
(a) Scope. The regulations of this section shall apply to all oil-burning equipment and shall include all equipment connected thereto, including tanks, piping, pumps, control devices, and all accessories. (b) Fuel oil. Fuel oil used in connection with oil burners and equipment to which this section applies shall have a flashpoint of not less than 100 degrees Fahrenheit as determined by the Tag close cup tester, and shall be hydrocarbon oil free from acid, grit, fibrous or other foreign matter likely to clog or injure the burners or valves. (c) Installation. (1) All oil burners shall be installed in an approved and workmanlike manner. Combustion chambers, etc., shall be cleaned in accordance with the requirements of section 18-402(i). (2) Where oil burners are installed in boilers or furnaces originally designed for other fuels, the ash door of the boiler or furnace shall be removed, or bottom ventilation otherwise provided to prevent an accumulation of vapors in the ash pit, unless the burner is of a type which mechanically purges the ash pit. (3) Manually operated dampers shall be such that they cannot close off more than 80 percent of the internal cross-sectional area of the smoke pipe. (4) Rooms in which oil burners are located shall be provided with adequate ventilation to assure continuous complete combustion of the oil. Where the oil burner is located in a room which does not have windows or doors to the outside air, such room shall be provided with an opening or duct to the outside air, or to a room which has windows or doors to the outside air. (5) Operating instructions. The installer of any oil fired furnace or boiler or oil conversion burner shall post in a conspicuous place near the appliance complete operating instructions for such appliance, including the installer's name and business address. (d) Construction and control. (1) All oil burners shall be of an approved type. (2) All oil burners shall be arranged to prevent abnormal discharge of oil in the event of ignition failure or premature flame extinguishment by automatic means specifically approved for the burner with which used. Oil burning space heaters shall be provided with such controls only if they are connected to an oil storage tank which is not an integral part of the space heater. (3) All oil burners shall be provided with an approved method for manually stopping the flow of oil to the burner from a point at a safe distance from the burner. (4) Automatically controlled oil burners used in connection with hot water, steam or warm air heating systems shall be equipped with approved automatic devices to stop the burner or reduce the fuel supply in the event of excessively high pressure or low water in the steam boiler or overheating in the hot water boiler or warm air furnace. (5) Oil burners which are supplied by gravity feed shall be equipped with an approved constant level valve. Such constant level valves if not a part of the burner of the oil tank shall be installed in the oil feed line at the tank, or as close thereto as possible.
(Code 1973, § 30.36.040)
Ask a question about Racine law
Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.