§ 18-402 — Gas appliances

Municipal Code of the City of Racine, Wisconsin (Codified through Ordinance No. 0082-26, adopted March 3, 2026. (Supp. No. 108)) · Racine Municipal Code § 18-402

Corpus is an independent public-information project, not the official City of Racine website. Stable reference: corpuslaw.us/code/28f67c3b-6707-4599-8530-7d7be8f4a73b

Sec. 18-402. - Gas appliances.

(a) Scope. The regulations of this section shall apply to all gas appliances utilizing material, manufactured or mixed gas and the gas utilization equipment shall be installed in accordance with American Standard Association Code ASA Z21.30-1969, which is also referred to as National Fire Protection Association Pamphlet No. 54 of the same date and entitled "Installation of Gas Appliances and Piping," or revisions thereto, or as otherwise regulated by this article. (b) Definitions. The following words, terms and phrases, when used in this section, shall have the meanings ascribed to them in this subsection, except where the context clearly indicates a different meaning: Draft hood means a device built into a gas appliance or made part of the flue or vent connector from a gas appliance, which is designed for the following purposes: (1) Ensuring the ready escape of the products of combustion in the event of no draft, backdraft, or stoppage beyond the draft hood. (2) Preventing a backdraft from entering the appliance. (3) Neutralizing the effect of stack action of the flue or vent upon the operation of the gas appliance. Flue or vent connector means the pipe connecting a gas appliance with the flue or vent. Gas appliance means any device utilizing gas fire, and especially designed to provide space heating. Gas conversion burner means a burner designed to supply gaseous fuel to a boiler or furnace which was originally designed to utilize another fuel. Gas regulator means a device for maintaining and controlling a uniform gas pressure. Space heater means a direct fired heating device mounted on or near the floor for heating the room in which the device is located without external heating pipes or ducts. Wall heater or furnace means a space heater which is supported from or recessed in the wall of the room being heated. (c) Venting. All gas appliances regulated in this section which require vents shall be vented to an approved flue or vent. (d) Labeling. All gas appliances shall be labeled with the manufacturer's identification mark, the maximum hourly input rate in Btu's per hour, the type of gas the burner is designed to use, and the symbol of the testing agency which approved the appliance. (e) Operating instructions. The installer of any gas fired furnace or boiler, or gas conversion burner, shall post in a conspicuous place near the appliance complete operating instructions for such appliance, including the installer's name and business address. (f) Safety measures. (1) All gas appliances shall be provided with a quarter-turn shutoff valve with an attached lever handle. Such valve should be located within six feet of the appliance, and so constructed that the valve can be easily and quickly closed. (2) The main shutoff valve shall shut off the entire supply of gas to the appliance, except where a pilot burner is used, in which case a separate manual shutoff shall be used to shut off the supply of gas to the pilot burner. Such pilot shutoff shall be installed between the meter and the main shutoff valve and shall be close to the main shutoff valve. (3) All automatically controlled gas appliances shall be provided with an automatic safety pilot device so constructed and adjusted that no gas can flow through the main burner unless the pilot light is burning. The operation of such device shall not depend on the closing of an electric circuit to shut off the main gas supply. (4) Automatic safety pilot devices shall be so adjusted that the main gas supply is shut off within three minutes after the pilot flame has been extinguished, except that on gas conversion burners with inputs in excess of 400,000 Btu's per hour such time shall be reduced to five seconds. (g) Gas burners. (1) Gas burners in gas appliances shall be properly installed and supported to prevent twisting, sliding, or dropping out of proper position. (2) All burners shall be so located that they will be readily accessible for operation, adjustment, or repair. (3) Baffles, when necessary, shall not interfere with proper combustion and shall be locked in position. (4) Where a gas space heating appliance is connected to a chimney or gas vent, the flue gas temperature at the inlet of the draft hood shall be set at not less than 350 degrees Fahrenheit for interior chimneys, and not less than 425 degrees Fahrenheit for exterior chimneys. (h) Automatic control. (1) All gas fired furnaces and hot water boilers, including those converted to gas firing, shall have automatic thermostatic control to close the automatic gas valve in the event that excessive high temperatures develop in the furnace or hot water boilers. (2) Automatic thermostatic control devices shall be provided for all gas fired steam boilers, as outlined in subsection (h)(1), in the event excessive pressures develop in the boiler or the water level in the boiler drops dangerously low. (3) Electrically operated safety controls shall not depend on the closing of an electrical circuit to shut off the gas supply to the appliance. (i) Gas conversion burners. (1) Before any gas conversion burner is installed, the combustion chamber flue passages, smoke pipe and chimney shall be thoroughly cleaned of all rust, soot and dirt. All rust and scale shall be scraped from the edges of the firing clinker or cleanout doors and the door jambs to obtain a tight fit. Leaky joints on cast iron furnaces shall be recemented. A smoke or other test shall be used to determine the effectiveness of the repairs. All doors on the boiler or furnace except the firing door shall be tightly sealed. The slots in the firing door shall be sealed. The fire brick in steel warm air furnaces shall be removed except where it is the only material that forms the sides of the fire pot. (2) The firing door on the furnace or boiler shall be arranged to open easily to relieve pressure by filing or removing the door catch and providing a spring device to hold the door closed. (3) Where a horizontal (in-shot) type gas conversion burner is installed in the ash pit of a dry base boiler or gravity warm air furnace, the ash pit shall be lined on the bottom and the sides up to the grate level with two inches of insulating firebrick or other approved insulation. (4) Movable smoke pipe dampers shall be removed. Other dampers which are an integral part of the boiler or furnace shall be removed or permanently locked in a position which does not interfere with the operation of the burner. (5) In down-draft or revertible flue type furnaces or boilers in which the flue passage turns downward after leaving the combustion chamber, the top of the combustion chamber or flue passage shall be vented to the smoke pipe by a one-inch diameter or larger pipe. The relief opening of a vertical or horizontal draft diverter should be at least one foot higher than the highest flue passage. (6) Where a bypass to the smoke pipe is provided in the construction of the furnace or the boiler at the point where the flue turns downward, the damper in the bypass may be partially opened and locked in place in lieu of the required one-inch pipe. (7) The cross-sectional area of the flue or vent connector shall be not less than one square inch per 7,500 Btu's per hour input of the gas conversion burner, but in no case shall the diameter of the flue or vent connector be less than that of the appliance flue collar. An orifice plate or neutral pressure point adjuster shall be inserted in the flue or vent connector to make necessary adjustment of the burner. This orifice plate shall be located between the unit and the diverter. (8) The draft diverter shall be located in the same room as the appliance. (j) Gas fired space heaters (room heaters). (1) Gas fired space heaters shall not be installed in bathrooms or shower rooms. (2) Gas fired space heaters may be installed in individual offices and in individual apartments if such installation is in compliance with the following: a. A space heater installed in normally closed rooms having a volume of less than 400 cubic feet shall be provided with an air intake to supply outside air for combustion purposes. b. Space heaters shall be provided with an automatic safety pilot device. c. The burner of the space heater shall be enclosed with a metal housing so arranged that there will be no open flame. The arrangement of the space heater shield shall be such that there will be no possibility of personal contact or combustible material contact with the flame or the housing enclosing the burner. d. Space heaters installed in sleeping rooms shall be provided with automatic safety pilot devices, and air for combustion shall be drawn directly from outside. e. Space heaters shall be installed with clearances to combustible construction as shown in the following table: Table K. Required Clearance of Space Heaters From Combustible Construction Type of space heater | Jacket, sides and rear (inches) | Projecting flue box or draft hood (inches) Circulation or radiating space heater | 6 | 2 Wall heaters (wall furnace) | none | — Gas, steam and hot water radiators | 6 | 2 f. Space heaters shall be placed so as not to cause a hazard to walls, floors, curtains, furniture, open doors or to the free movement of persons within the room. g. Gas fired space heaters which have been approved for mounting on combustible floors shall be mounted in accordance with such approval. Other types of gas fired space heaters shall be mounted on noncombustible floors or on combustible floors as regulated in this article.

(Code 1973, § 30.36.030)

Ask a question about Racine law

Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.