Sec. 3-80. - Enclosures for outline lighting; requirements.

(a) Enclosures for outline lighting shall conform to the following: (1) Conductors and Terminals. Cabinets and outline troughs shall have conductors and terminals, except the supply leads, enclosed; (2) Cutouts, Flashers, etc. Cutouts, flashers and similar devices shall be in a separate compartment. They shall be enclosed in approved metal boxes, the doors of which shall be arranged so that they can be opened without removing obstructions or finished parts of the enclosure; (3) Enclosure Exposed to the Weather. Enclosures for outside use shall be weatherproof and shall have an ample number of drain holes, each not larger than one-half (½) of an inch or smaller than one-fourth (¼) of an inch. Wiring connections shall not be made through the bottoms of enclosures exposed to the weather, unless the enclosures are of the rain tight type; (4) Material. Outline lighting shall be constructed of metal or other noncombustible material. Wood may be used for external decoration if placed at least two (2) inches from the nearest lampholder or current-carrying part; (5) Strength. Enclosures shall have ample strength and rigidity; (6) Thickness of Metal. Sheet copper shall be at least twenty-eight thousands (.028) of an inch. Sheet steel may be of No. 28 USS gauge, One hundred and forty nine thousands (.0149) of an inch; except, that for outline lighting, sheet steel shall be of No. 24 USS gauge, two hundred and thirty-nine thousands (.0239), of an inch, unless ribbed, corrugated or embossed over its entire surface, then it may be of No. 26 USS gauge, one hundred and seventy-nine thousands (.0179) of an inch; (7) Protection of Metal. All metallic parts of enclosures shall be galvanized or otherwise protected from corrosion; (8) Tube Terminals. The terminals shall be so designed that the tubing can be replaced without the necessity of exposing uninsulated live parts. If the spring contact type of receptacle is used, it shall be so designed that, even with the tube removed, the live spring will be recessed a distance equal to three (3) times the diameter of the receptacle opening. It is recommended that the primary circuit be controlled by a relay that will open the circuit when a tube in the secondary circuit is broken or removed. Live parts shall be protected by barriers which require other than ordinary tools, such as pliers and screw-drivers, for removal, unless access to the parts requires the disconnection of the primary circuit.

(Code 1962, § 21-19)

Ask a question about South Bend law

Corpus searches the South Bend sections it holds and shows the ones that match, with their citations. Free, no sign-in.