Sec. 3-91. - Electrodes for inside neon gas window signs.

(a) The tube terminals shall comply with one of the following: (1) Project within an enclosure and be separated from grounded metal by a minimum of one and one-half (1½) inches of air or by an approved, nonabsorptive, noncombustible insulating bushing or receptacle suitable for the voltage. (2) In the exposed type, when not easily accessible, hanging free in air and not less than one and one-half (1½) inches from conducting or combustible material, shall be enclosed by an approved sleeve of nonconductive and nonbreakable type. This sleeve shall overlap all live parts by at least one and one-half (1½) inches and shall be of a type which will afford the protection intended of it and approved for the purpose.