Sec. 3-85. - Terminals and receptacles for electric discharge tubing used in outline lighting with over six hundred volts.
(a) Terminals and receptacles for electric discharge tubing shall comply with the following: (1) Terminals. The terminals of the tubing shall be inaccessible to unqualified persons and isolated from combustible material and grounded metal or shall be enclosed. If enclosed, they shall be separated from grounded metal and combustible material and grounded metal or shall be enclosed. If enclosed, they shall be separated from grounded metal and combustible material by noncombustible, nonabsorptive, insulating material approved for the purpose or by one and one-half (1½) inches of air. Terminals shall be relieved from stress by the independent support of the tubing; (2) Tube Connections other than with Receptacles. If tubes do not terminate in receptacles designed for the purpose, all live parts of tube terminals and conductors shall be so supported as to maintain a separation of at least one and one-half (1½) inches between conductors and any grounded metal; (3) Receptacles. Electrode receptacles for the tubing shall be of noncombustible, nonabsorptive, insulating material approved for the purpose; (4) Receptacles and Bushing Seals. A flexible, nonconducting seal may be used to close the opening between the tubing and the receptacle or bushing against the entrance of dust or moisture. This seal shall not be in contact with grounded conductive material and shall not be depended upon for the insulation of the tubing; (5) Enclosures of Metal. Metal enclosures for electrodes shall be of not less than No. 24 USS gauge, two hundred and thirty-nine thousands (.0239) of an inch sheet metal; and, (6) Enclosures of Insulating Material. Enclosures of insulating material shall be noncombustible, nonabsorptive and approved for the voltage of the circuit.
(Code 1962, § 21-21)
Ask a question about South Bend law
Corpus searches the South Bend sections it holds and shows the ones that match, with their citations. Free, no sign-in.