Sec. 3-93. - Wiring above six hundred volts for inside neon gas window signs.
(a) Conductors for circuits operating at a potential in excess of six hundred (600) volts shall be of a type approved for the purpose, suitable for the voltage involved and shall be not smaller than No. 14 and shall, if within a sign or other enclosure, be supported on insulating supports placed not more than two (2) feet apart which separate the wires at least two (2) inches from each other and from conducting materials. (b) Conductors within a sign shall have rubber compound or other approved insulation; provided, that where conductors are entirely enclosed within a sign enclosure and the enclosure cannot be opened without breaking the primary circuit, they may be bare. (c) Sharp bends in the conductors shall be avoided. (d) Conductors shall be installed in conduit, electrical metallic tubing or armored cable. Approved insulating bushings shall be used where the gas tube cable enters or leaves the conduit or electrical metallic tubing. (e) Where conductors hang freely in air away from combustible or conducting material, as in some window displays, and where not subject to mechanical injury they need not be otherwise protected.
(Code 1962, § 21-22)
Ask a question about South Bend law
Corpus searches the South Bend sections it holds and shows the ones that match, with their citations. Free, no sign-in.