§ 3-82 — Installation of conductors for outline lighting of more than six hundred volts

Code of Ordinances of the City of South Bend, Indiana (Codified through Ordinance No. 11254-26, enacted February 9, 2026 (Supp. No. 65)) · South Bend Code of Ordinances § 3-82

Corpus is an independent public-information project, not the official City of South Bend website. Stable reference: corpuslaw.us/code/a0dcaf2c-5856-4a30-84f9-61943837ccc0

Sec. 3-82. - Installation of conductors for outline lighting of more than six hundred volts.

(a) Conductors shall be installed as follows: (1) Wiring Method. Conductors shall be installed in rigid or flexible metal conduit. Conductors may be run from the ends of tubing to the grounded midpoint of transformers specifically designed for the purpose and provided with terminals at the midpoint. Where such connections are made to the transformer grounded midpoint, the connections between the high-voltage terminals of the transformer and the line ends of the tubing shall be as short as possible; (2) Insulation and Size. Conductors shall be of a type approved for the purpose and the voltage of the circuit, and shall be not smaller than No. 14; (3) Bends in Conductors. Sharp bends in the conductors shall be avoided; (4) Conductors in Raceways. If the conductors are covered with lead or other metal sheathing, the covering shall extend beyond the end of the raceway, and the surface of the cable shall not be injured where the covering terminates. In damp or wet locations, the insulation on all conductors shall extend beyond the metal covering or raceway at least four (4) inches for voltages over ten thousand (10,000); three (3) inches for voltages over five thousand (5,000), but not exceeding ten thousand (10,000); and two (2) inches for voltages of five thousand (5,000) or less. In dry locations, the insulation shall extend beyond the end of the metal covering or raceways not less than two and one-half (2½) inches for voltages over ten thousand (10,000); two (2) inches for voltages over five thousand (5,000), but not exceeding ten thousand (10,000); and one and one-half (1½) inches for voltages of five thousand (5,000) or less. For conductors at grounded midpoint terminals, no spacing is required. No more than twenty (20) feet of cable from a single transformer shall be run in metal raceway where the potential between the cable and the raceway is more than five thousand (5,000) volts.

(Code 1962, § 21-21)