§ 3-89 — Transformers for inside neon gas window signs; requirements

Code of Ordinances of the City of South Bend, Indiana (Codified through Ordinance No. 11254-26, enacted February 9, 2026 (Supp. No. 65)) · South Bend Code of Ordinances § 3-89

Corpus is an independent public-information project, not the official City of South Bend website. Stable reference: corpuslaw.us/code/1d9e2c23-2394-49d5-85e6-1052621cf11f

Sec. 3-89. - Transformers for inside neon gas window signs; requirements.

(a) Transformers shall be of types with no exposed terminals, shall be marked with the marker's name, input rating and open circuit high tension voltage. The marking shall be visible for inspection after installation. Where the transformer is located above the ceiling of the window, the high tension cable shall be in conduit and the conduit locked into the transformer enclosure. (b) Except by special permission, transformers shall be of types where ratings do not exceed thirty (30) milliamperes secondary or four hundred and fifty (450) volt ampere primary, not exceeding fifteen thousand (15,000) volts open circuit secondary, with an additional one thousand (1,000) volts for test. (c) Where special permission has been obtained for installations exceeding thirty (30) milliamperes, all tube electrodes shall be enclosed and door switches installed on all enclosures which, by opening, will break the primary circuit supply to the transformers and vacuum tube terminals. (d) The capacity of an overcurrent device protecting one (1) or more transformers shall be limited to fifteen (15) amperes at one hundred and twenty-five (125) volts.

(Code 1962, § 21-22)

Ask a question about South Bend law

Corpus searches the South Bend sections it holds and shows the ones that match, with their citations. Free, no sign-in.