Sec. 3-84. - Tubing requirements in outline lighting with more than six hundred volts.

(a) Electric discharge tubing shall conform to the following: (1) Design. The tubing shall be of such length and design as not to cause a continuous over-voltage on the transformer; (2) Support. Tubing shall be adequately supported on noncombustible, nonabsorptive supports. Tubing supports should, if practicable, be adjustable; (3) Contact with Flammable Material and other Surfaces. The tubing shall be free from contact with flammable material and shall be located where not normally exposed to mechanical injury. If operating in excess of seven thousand five hundred (7,500) volts, the tubing shall be supported on noncombustible, nonabsorptive, insulating supports, which maintain a spacing of not less than one-fourth (¼) of an inch between the tubing and the nearest surface.