For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-9-153 — Test gage connection and relief valve for hydraulic elevators

2019 Detroit City Code (Supp. No. 4: codified through Ordinance No. 2024-17, effective March 26, 2024, and Ordinance No. 2024-32, effective June 25, 2024) · Detroit City Code § 8-9-153

Corpus is an independent public-information project, not the official City of Detroit website. Stable reference: corpuslaw.us/code/a5fa3154-6436-48ce-9daa-c6ce92f3fb2d

Sec. 8-9-153. - Test gage connection and relief valve for hydraulic elevators.

(a) All new hydraulic elevators, and all existing hydraulic elevator installations undergoing cylinder replacement, shall be provided with a one-fourth-inch pipe size snap-on valve connection between the pump and the check valve for attaching a pressure gage to determine the discharge pressure of the pump. All new hydraulic elevators, and all existing hydraulic elevator installations undergoing cylinder replacement, shall be provided with an approved relief valve in accordance with Section 3.19.4.2.1 of the ASME Code. The relief valve shall be preset to open at a full flow not greater than 125 percent of the working pressure. (b) When the relief valve for the hydraulic system is incorporated into a compound valve which provides control functions, the adjustment of which affect the setting or operation of the relief valve, a separate and independent relief valve shall be installed in accordance with Section 3.19.4.2.1 of the ASME Code, excluding Subsection (b) of the section.

(Code 1964, § 7.8; Code 1984, § 7.8; Ord. No. 307-H, § 1(7.8), eff. 3-2-1979; Ord. No. 03-97, § 1(7.8), eff. 3-10-1997)

Ask a question about Detroit law

Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.