§ 8-9-162 — Limited-use/limited-application elevators

2019 Detroit City Code (Supp. No. 4: codified through Ordinance No. 2024-17, effective March 26, 2024, and Ordinance No. 2024-32, effective June 25, 2024) · Detroit City Code § 8-9-162

Corpus is an independent public-information project, not the official City of Detroit website. Stable reference: corpuslaw.us/code/0ec2e14c-3a81-4b85-ad36-aacbe8018654

Sec. 8-9-162. - Limited-use/limited-application elevators.

(a) In addition to the requirements of the Section 5.2 of the ASME Code and this article, a limited-use/limited-application elevator shall comply with the following requirements: (1) Only one limited-use/limited-application elevator per structure shall be allowed; (2) The installation of a limited-use/limited-application elevator shall be limited to those structures that have a total square footage of not more than 20,000 square feet, except for one- or two-family dwellings, provided, that where the area to be accessed is 10,000 square feet or less, a limited-use/limited-application elevator may be installed in the structure; (3) The minimum rated load of the limited-use/limited-application elevator shall confirm to Section 2.16.1 of the ASME Code. The maximum rated load shall not exceed 635 kilograms (1,400 pounds); (4) A limited-use/limited-application elevator shall not have a vertical rise of more than 25 feet; and a. Where the elevator has only a front opening, it shall serve only two floors; or b. Where the elevator has a front and rear opening and there is an intermediate level between two floors, three landings shall be permitted; (5) The rated speed of a limited-use/limited-application elevator shall not be more than 30 feet per minute. Where the distance to be traveled by such a device is more than six feet, the minimum speed of the device shall not be less than 15 feet per minute; (6) All exposed equipment on a limited-use/limited-application elevator shall be guarded to protect against accidental contact that may cause bodily injury; (7) The frame of a limited-use/limited-application elevator shall be constructed of metal; (8) The clear floor area of the car below the handrail shall be a minimum of 54 inches long, a minimum of 30 inches wide, and not be more than 13 square feet. The controls shall be located so as to not infringe upon the minimum 32-inch by 54-inch clear space below the handrail; (9) All welding on the limited-use/limited-application elevator shall be in accordance with the ASME Code; (10) The limited-use/limited-application elevator shall be fully enclosed on the top and on any side that is not used as an entrance or as an exit, and such enclosures shall conform to requirements of Section 2.14 of the ASME Code; (11) Except where vision panels are provided, a limited-use/limited-application elevator door without openings shall be provided at each entrance to the elevator along with an electric contact device door or electric contact gate conforming to the requirements of Section 2.12.5 of the ASME Code. A door or gate handle shall be provided for manually-operated doors and shall be of the lever or bar type. The top of the handle shall not be more than 48 inches above the elevator floor; (12) A handrail that extends the full length of the one long side of the platform shall be provided on the control side at a height of 36 inches to the top of the handrail above the finished floor of the limited-use/limited-application elevator. The bottom of the handrail shall be not less than 32 inches above the finished floor of the device; (13) Except for direct-plunger hydraulic elevator, each limited-use/limited-application elevator shall be equipped with a safety mechanism and overspeed governor which, in the event the device descends at a rate of more than 150 percent of the rated speed, shall interrupt the electrical power supply to the brake and motor, grip the rails or by other means firmly bring the car loaded with the rated load to a stop within a traveling distance of 1.5 inches, and hold the elevator stationary. After use, the safety mechanism shall only be capable of release when the car is raised; (14) The operating controls from any control station shall be of a momentary pressure automatic type. Push/pull-type and recessed controls on these devices are prohibited. Metal tactile numbers shall be provided adjacent to the device's control buttons and switches; (15) The control station shall be mounted or installed on the side of the limited-use/limited-application elevator within the reach of an individual in a wheelchair. The controls shall be mounted at a height between 36 inches and 48 inches above the finished floor; (16) Hall controls shall be mounted on the latch side of the door and shall be located between 36 inches and 48 inches above the finished floor; (17) The control on the limited-use/limited-application elevator shall include: a. An emergency signaling device which conforms to the requirements of Section 8-9-192 of this Code and be operable at all times; and b. An emergency stop switch as required by Section 8-9-158(6) of this Code; (18) A separate fused disconnecting means, or circuit breaker, shall be provided on a separate electrical circuit in a machine room that is not accessible to the general public; (19) Where required, a slack cable switch shall comply with requirements of Section 2.26.2.1 of the ASME Code; (20) The installation of pipes or ducts conveying gases, vapors, or liquids in hoistways, machine rooms, or machinery spaces shall comply with the requirements of Section 2.8.2 of the ASME Code. Only electrical wiring used directly in connection with a limited-use/limited-application elevator may be installed inside the hoistway, machinery space, machine room, or control room and shall comply with the requirements of Section 2.8.1.1 of the ASME Code. Electrical wiring and components in a limited-use/limited-application elevator and their installation shall comply with the requirements of Chapter 8, Article III, of the 2019 Detroit City Code, Electrical Code; (21) The hoistway for the elevator shall be fully enclosed. The hoistway enclosure and the entrance assemblies shall have a fire resistance rating of not less than one hour. The enclosure shall not deflect more than one inch when subjected to a force of 100 pounds applied horizontally at any point. In addition, where an elevator is exposed to the outside elements, a permanent weatherproof enclosure, which shall be made of approved construction materials, shall be provided for the device. (22) The hoistway entrances of a limited-use/limited-application elevator shall be guarded by doors of unperforated construction. The doors shall be of the delayed self-closing type that are not less than 80 inches in height, and provide a minimum clear opening width of 30 inches when the doors are on the short side of the platform or a minimum clear opening width of 40 inches when the doors are on the long side of the platform. The doors shall have an approved combination mechanical lock and electrical contacts, and shall open only when the car platform is within one-half inch of the floor level; (23) The running clearance between the edge of the platform sill and the landing sill shall not be less than three-eighths of an inch or more than three-fourths of an inch. The distance between the edge of the hoistway landing sill to the hoistway face of the door shall not be more than three inches. The distance between the hoistway face of the landing door and the limited-use/limited-application device door shall not be more than five inches; (24) A minimum 30 second non-interference feature shall be provided and shall assure that the first call registered will control the operation of the elevator; (25) The limited-use/limited-application elevator platform floor surfacing shall be of a slip-resistant type; (26) Where a platform of a limited-use/limited-application elevator does not have an under-platform clearance of 48 inches, or the maximum rise to the elevator, whichever is less, when resting on its bottom mechanical limits, the elevator shall incorporate a means which, when appropriately positioned during maintenance, will mechanically prevent the platform from descending closer than 48 inches to the pit floor at rated speed with rated load in the down direction. Instructions shall be posted in the pit; (27) Platform guide rails shall be of metal construction. Steel construction shall conform to the requirements of Section 2.23.2.1 of the ASME Code, and metals other than steel shall conform to Section 2.23.2.2 of the ASME Code. The top and bottom ends of each run of guide rail shall be so located in relation to the extreme positions of travel of the barrier-free device that the device guiding members cannot travel beyond the ends of the guide rails. Fastenings, deflection, and joints shall conform to the requirements set forth in Sections 2.23.2, 2.23.5, and 2.23.8 of the ASME Code; (28) Machines, machinery, and sheaves shall be supported and maintained in place to prevent any part from becoming loose of displaced under the conditions imposed in service and shall comply with the requirements of Section 2.9 of the ASME Code; (29) A stop switch shall be provided on the top of a limited-use/limited-application device; (30) A production model of a limited-use/limited-application elevator shall be subjected to a static load test to establish that all structural components of the elevator will withstand stresses of ten times the rated load of the elevator and to ensure a factor of safety of not less than ten. A registered professional engineer shall certify the safety factor, and affix his or her signature and seal to the certification; (31) A limited-use/limited-application elevator shall not be used for moving freight; and (32) A limited-use/limited-application elevator shall be serviced and examined for defects at least once every 90 days by an unlimited-elevator journeyperson who is licensed by the City. (b) The following components of limited-use/limited-application elevators shall conform to, and be tested in accordance with, the indicated requirements: (1) The driving machine shall be of the traction or direct-plunger hydraulic type. Traction machines shall conform to the requirements of Section 2.24 of the ASME Code; (2) Terminal stopping devices shall be provided for traction driving machines and shall conform to the requirements of Section 2.25 of the ASME Code; (3) Tests for traction driving machines shall be conducted in accordance with the requirements of Sections 8.10, 8.11.2.2, and 8.11.1.3 of the ASME Code; (4) Direct-plunger hydraulic driving machines shall conform to the requirements of Sections 3.18.1.1 and 3.19.1 of the ASME Code; (5) Terminal stopping devices and control circuits shall be provided for direct-plunger machines and shall conform to the requirements of Sections 3.25.1 and 3.26.6 of the ASME Code; and (6) Tests for direct-plunger hydraulic machines shall be conducted in accordance with the requirements of Section 8-9-178 of this Code.

Ask a question about Detroit law

Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.