For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-9-159 — Installation of pipes or ducts conveying gases, vapors, or liquids in hoistways, machine rooms, or machinery spaces

2019 Detroit City Code (Supp. No. 4: codified through Ordinance No. 2024-17, effective March 26, 2024, and Ordinance No. 2024-32, effective June 25, 2024) · Detroit City Code § 8-9-159

Corpus is an independent public-information project, not the official City of Detroit website. Stable reference: corpuslaw.us/code/f6aaca05-8aca-4414-901c-d3573d828a86

Sec. 8-9-159. - Installation of pipes or ducts conveying gases, vapors, or liquids in hoistways, machine rooms, or machinery spaces.

(a) Steam and hot water pipes are permitted to be installed in hoistways, machinery spaces, machine rooms, or control rooms for the purpose of heating these areas only, subject to the following: (1) Heating pipes shall convey only low pressure steam [15 PSI (100 kPa) or less] or hot water [212 degrees Fahrenheit (100 degrees Celsius) or less]; (2) All risers and return pipes shall be located outside the hoistway; and (3) Traps or shutoff valves shall be provided in readily accessible locations outside the hoistway. (b) Ducts for heating, cooling, ventilation, and venting these spaces are permitted to be installed in the hoistway, machine spaces, machinery room, or control room. Other pipes or ducts conveying gases, vapors or liquid, and not used in connection with the operation of the elevator, shall not be installed in any hoistway, machinery space, machine room, or control room.

Ask a question about Detroit law

Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.