25.06.442 Section 604.7 Amended; Identification.
Section 604.7 of the International Mechanical Code is amended to read as follows: External duct insulation, except spray polyurethane, foam, and factory-insulated flexible duct shall be legibly printed or identified at intervals not greater than 36 inches (914mm) with the name of the manufacturer, the thermal resistance R-value at the specified installed thickness, and the flame spread and smoke-developed indexes of the composite materials. All duct insulation product R-values shall be based on insulation only, excluding air films, vapor retarders, or other duct components, and shall be based on tested C-values at 75°F (24°C) mean temperature at the installed thickness, in accordance with recognized industry procedures. The installed thickness of duct insulation used to determine its R-value shall be determined as follows: (1) 1. For duct board, duct liner, and factory-made rigid ducts not normally subjected to compression, the nominal insulation thickness shall be used. (2) 2. For duct wrap, the installed thickness shall be assumed to be 75 percent (25 percent compression) of nominal thickness. (3) 3. For factory-made flexible air ducts, the installed thickness shall be determined by dividing the difference between the actual outside diameter and nominal inside diameter by two. (4) 4. For spray polyurethane foam, the aged R-value per inch, measured in accordance with recognized industry standards, shall be provided to the customer in writing at the time of foam application. (5) 5. Ducts in unconditioned attics and outside of the building envelope, including supply and return boots, shall meet the required R-value with internal or external approved duct insulation without the addition of building or other types of insulation. R-values are: Supply R-8, Return R-8, Exhaust R-4, Outside air R-4. (: Ord. 20526 §64, August 21, 2017).
(Ord. 21815 §44; December 15, 2025; Ord. 21113 §36; August 23, 2021)
Ask a question about Lincoln law
Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.