25.06.389 Section 507.2.7 Amended; Type I Hoods Penetrating a Ceiling.

Section 507.2.7 of the International Mechanical Code is hereby amended to read as follows: Type I hoods or portions thereof penetrating a ceiling, wall, or furred space shall comply with Section 506.3.11. Field applied grease duct enclosure systems as addressed in section 506.3.11.2 may be utilized to satisfy the requirements of this Section. The installation of field applied enclosures will require two (2) layers with overlapping joints. (: Ord. 20526 §54, August 21, 2017).

(Ord. 21113 §27; August 23, 2021)