§ 25.06.362 — Section 504.11 Amended; Common Exhaust Systems for Clothes Dryers Located in Multistory Buildings

Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 25.06.362

Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/b39776c2-bbcc-4ff9-92d0-c8e3bbf33c29

25.06.362 Section 504.11 Amended; Common Exhaust Systems for Clothes Dryers Located in Multistory Buildings.

Section 504.11 of the International Mechanical Code is amended to read as follows: 504.11. Common exhaust systems for clothes dryers located in multistory buildings. Where a common multistory duct system is designed and installed to convey exhaust from multiple clothes dryers, the construction of the system shall be in accordance with all of the following: (1) 1. The shaft in which the duct is installed shall be constructed and fire resistance rated as required by the International Building Code. (2) 2. Dampers shall be prohibited in the exhaust duct. Penetrations of the shaft and ductwork shall be protected in accordance with Section 607.5.5, Exception 2. (3) 3. Rigid metal ductwork shall be installed within the shaft to convey the exhaust. The ductwork shall be constructed of sheet steel having a minimum thickness of 0.0187 inch (No. 26 gage) and in accordance with SMACNA Duct Construction Standards. (4) 4. The ductwork within the shaft shall be designed and installed without offsets. (5) 5. The exhaust motor design shall be in accordance with Section 503.2. (6) 6. The exhaust fan motor shall be located outside of the airstream. (7) 7. The exhaust fan shall run continuously. (8) 8. Exhaust fan operation shall be monitored in an approved location and shall initiate an audible or visual signal when the fan is not in operation. (9) 9. Makeup air shall be provided for the exhaust system. (10) 10. A cleanout opening shall be located at the base of the shaft to provide access to the duct to allow for cleaning and inspections. The finished opening shall be not less than 12 inches by 12 inches. (11) 11. Screens shall not be installed at the termination. (12) 12. The common multi-story duct system shall serve only clothes dryers and shall be independent of other exhaust systems. (: Ord. 20526 §45, August 21, 2017).

(Ord. 21815 §31; December 15, 2025; Ord. 21113 §20; August 23, 2021)