§ 25.06.368 — Section 505.4 Amended; Makeup Air Required

Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 25.06.368

Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/3382dc63-7a1b-4d9a-8f15-05d6f6718a0f

25.06.368 Section 505.4 Amended; Makeup Air Required.

Section 505.4 of the International Mechanical Code is amended to read as follows: 505.4 Makeup air required. Exhaust hood systems capable of exhausting in excess of 400 cfm (0.19 m3/s) shall be provided with makeup air at a rate approximately equal to the exhaust air rate. Exception: Residential kitchen exhaust may exceed 400 cfm provided makeup air is provided into the structure. The makeup air shall be controlled by a motorized damper that is electrically interlocked to open with operation of the kitchen exhaust fan. The makeup air shall be conditioned to within 10 degrees F of the space designed temperature during the winter heating mode. The makeup air may be conditioned by circulation with a forced air furnace system or by other means approved by the Building Official. Kitchen exhaust exceeding 400 cfm will not require make up air in homes with no open flues or use of interior combustion air. ().

(Ord. 21815 §33; December 15, 2025)