§ 25.06.355 — Section 501.3.1 Amended; Location of Exhaust Outlets
Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 25.06.355
Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/e435800b-9b3d-4bec-815d-370a001b233d
25.06.355 Section 501.3.1 Amended; Location of Exhaust Outlets.
Section 501.3.1 of the International Mechanical Code is amended to read as follows: 501.3.1 Location of exhaust outlets. The termination point of exhaust outlets and ducts discharging to the outdoors shall be located with the following minimum distances: (1) 1. For ducts conveying explosive or flammable vapors, fumes, or dusts: 30 feet from property lines; 10 feet from operable openings into buildings; 6 feet from exterior walls and roofs; 30 feet from combustible walls and operable openings into buildings which are in the direction of the exhaust discharge; 10 feet above adjoining grade. (2) 2. For other product-conveying outlets: 10 feet from the property lines; 3 feet from exterior walls and roofs; 10 feet from operable openings into buildings; 10 feet above adjoining grade. (3) 3. For all environmental air duct exhaust: 3 feet (914 mm) from property lines; 3 feet (914 mm) from operable openings into buildings for all occupancies other than Group U, and 10 feet (3048 mm) from mechanical air intakes. Such exhaust shall not be considered hazardous or noxious. Separation is not required between intake air openings and living space exhaust air openings of an individual dwelling unit or sleeping unit where an approved factory-built intake/exhaust combination termination fitting is used to separate the air streams in accordance with the manufacturer’s instructions. Exception: Environmental air exhaust from a dwelling unit shall be exempt from the 3 foot clearance from operable openings into the dwelling unit from which it originates. Residential bath exhaust and kitchen exhaust must be a minimum of 3 feet from mechanical air intakes. (4) 4. Exhaust outlets serving structures in flood hazard areas shall be installed at or above the elevation required by Section 1612 of the International Building Code for utilities and attendant equipment. (5) 5. For specific systems see the following sections: 5.1 Clothes dryer exhaust, Section 504.4. 5.2 Kitchen hoods and other kitchen exhaust equipment, Sections 506.3.13, 506.4, and 506.5. 5.3 Dust stock and refuse conveying systems, Section 511.2. 5.4 Subslab soil exhaust systems, Section 512.4. 5.5 Smoke control systems, Section 513.10.3. 5.6 Refrigerant discharge, Section 1105.7. 5.7 Machinery room discharge, Section 1105.6.1. (: Ord. 20526 §42, August 21, 2017).
(Ord. 21815 §27; December 15, 2025)
Ask a question about Lincoln law
Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.