§ 25.06.357 — Section 504.2 Amended; Exhaust penetrations

Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 25.06.357

Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/71804218-d5a0-47bb-83aa-5ee8f3597017

25.06.357 Section 504.2 Amended; Exhaust penetrations.

Section 504.2 of the International Mechanical Code is amended to read as follows: Where a clothes dryer exhaust duct penetrates a wall or ceiling membrane, the annular space shall be sealed with noncombustible material, approved fire caulking or a noncombustible dryer exhaust duct wall receptacle. Ducts that exhaust clothes dryers shall not penetrate or be located within any fire blocking, draftstopping or any wall, floor/ceiling or other assembly required by the International Building Code to be fire-resistance rated, unless such duct is constructed of galvanized steel or aluminum of the thickness specified in Section 603.4 and the fire-resistance rating is maintained in accordance with the International building Code. Fire dampers, combination fire/smoke dampers, and any similar devices that will obstruct the exhaust flow shall be prohibited in clothes dryer ducts. Exception: Dryer vents may penetrate a floor ceiling assembly that is required to be fire resistance rated provided that the dryer vent is draped with unfaced R-19 fiberglass insulation. (See diagram next page) (: Ord. 20526 §43, August 21, 2017). [image omitted; see the official code] [image omitted; see the official code] |

(Ord. 21815 §29; December 15, 2025)

Ask a question about Lincoln law

Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.