25.06.360 Section 504.4 Amended; Exhaust Installation.

Section 504.4 of the International Mechanical Code is amended to read as follows: 504.4 Exhaust installation. Dryer exhaust ducts for clothes dryers shall terminate on the outside of the building and shall be equipped with a backdraft damper. Screens shall not be installed at the duct termination. Ducts shall not be connected or installed with sheet metal screws or other fasteners that will obstruct the exhaust flow. Clothes dryer exhaust ducts shall not be connected to a vent connector, vent, or chimney. Clothes dryer exhaust ducts may extend into or through ducts or plenums provided their connections are sealed airtight.

(Ord. 20526 §44, August 21, 2017)