§ 25.06.423 — Section 601.5 Amended; Return Air Openings

Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 25.06.423

Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/99a11257-111d-45b4-a830-7f0c95614477

25.06.423 Section 601.5 Amended; Return Air Openings.

Section 601.5 of the International Mechanical Code is amended to read as follows: Outdoor or return air for a forced-air heating system shall not be taken from the following locations: (1) 1. Less than 10 feet from an appliance open combustion chamber, draft hood, or vent outlet, a vent opening from a plumbing drainage system, or the discharge outlet of an exhaust fan, unless the outlet is 3 feet above the outdoor air inlet. (2) 2. Where there is the presence of objectionable odors, fumes, or flammable vapors; or where located less than 10 feet above the surface of any abutting public way or driveway; or where located at grade level by a sidewalk, street, alley, or driveway. (3) 3. A hazardous or insanitary location or a refrigeration machinery room as defined in this code. (4) 4. A room or space, the volume of which is less than 25 percent of the entire volume served by such system. Where connected by a permanent opening having an area sized in accordance with Sections 918.2 and 918.3, adjoining rooms or spaces shall be considered as a single room or space for the purpose of determining the volume of such rooms or spaces. Exception: The minimum volume requirement shall not apply where the amount of return air taken from a room or space is less than or equal to the amount of supply air delivered to such room or space. (1) 5. A bathroom, toilet room, garage, mechanical room, boiler room, furnace room, or unconditioned attic. Exception 1: A bathroom large in comparison may have a return air inlet. Exception 2: Where return air intakes are located not less than 10 feet from cooking appliances, and serve the kitchen area only, taking return air from a kitchen shall not be prohibited. Exception 3: A walk-in closet provided with a supply air outlet shall not be prohibited from having a return air inlet. (1) 6. An unconditioned crawl space by means of direct connection to the return side of a forced air system. Transfer openings in the crawl space enclosure shall not be prohibited. (2) 7. A room or space containing a fuel-burning appliance where such room or space serves as the sole source of return air. Exceptions: 7.1 This shall not apply where the fuel-burning appliance is a direct-vent appliance. 7.2 ​​​​​​​This shall not apply where the room or space complies with the following requirement: 7.2.1. ​​​​​​​The return air shall be taken from a room or space having a volume exceeding 1 cubic foot for each 10 Btu/h (9.6 L/W) of combined input rating of all fuel-burning appliances therein. 7.2.2. ​​​​​​​The volume of supply air discharged back into the same space shall be approximately equal to the volume of return air taken from the space. 7.2.3. ​​​​​​​Return-air inlets shall not be located within 10 feet of any appliance firebox or draft hood in the same room or space. 7.3 ​​​​​​​This shall not apply to rooms or spaces containing solid-fuel-burning appliances, provided that return-air inlets are located not less than 10 feet from the firebox of the appliances. (1) 8. Return air shall not be taken from indoor swimming pool enclosures and associated deck areas. Exceptions: 8.1 Where the air from such spaces is dehumidified in accordance with Section 403.2.1, Item 2. 8.2 Dedicated HVAC systems serving only such spaces. ().

(Ord. 21815 §41; December 15, 2025; Ord. 21113 §31; August 23, 2021)

Ask a question about Lincoln law

Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.