§ 3-903.10 — New apartment buildings
Code of the City of Harrisburg, Pennsylvania · Harrisburg Code § 3-903.10
Corpus is an independent public-information project, not the official City of Harrisburg website. Stable reference: corpuslaw.us/code/e1d34009-d5cc-404b-b4f4-8cc626d4cb12
§ 3-903.10: New apartment buildings.
A. This section establishes life safety requirements for all new apartment buildings and structures housing apartments. This includes buildings or structures containing three or more dwelling units with independent cooking and bathroom facilities, whether designated as apartment house, tenement, garden apartment, townhouse, condominium or by any other name. B. The occupant load in numbers of persons for whom exits are to be provided shall be one person per 200 square feet gross floor area or the maximum probable population of any room or section under consideration, whichever is greater. C. Every dwelling unit shall have access to at least two separate exits remote from each other. An exception to this is any dwelling unit which has an exit directly to the street or yard at ground level or by way of an outside stairway or an enclosed stairway with a fire-resistance rating of one hour or more serving that apartment only and not communicating with any floor below the level of exit discharge. D. All means of egress and exits shall be illuminated. Illumination of means of egress shall be continuous. E. The floors of means of egress shall be illuminated at all angles and points of corridors and passageways, stairways, landings of stairs, and stairway and exit doors. F. Any apartment building with more than three dwelling units or greater than three stories in height shall have emergency lighting. The emergency lighting systems shall be so arranged as to provide the required illumination automatically in the event of any interruption of normal lighting, such as a power failure of a public utility or other power source, opening of a circuit breaker or fuse, or any manual act(s). G. All means of egress shall be marked. Exit signs shall be posted in all apartment buildings requiring more than one exit. H. No door in any means of egress shall be locked against egress when the building is occupied. Locks, if provided, shall not require the use of a key, tool, or special knowledge or effort for operation from the inside of the building. No ordinary double-cylinder locks or chain locks meet the provisions of this section. I. All new apartment buildings with more than three stories or with more than 10 living units shall be provided with an approved fire alarm system. J. In all new apartment buildings the required fire alarm system shall be initiated upon the operation of the automatic sprinkler system, in addition to the manual initiation. Occupant notification shall be accomplished automatically without delay by an internal audible alarm signal. In buildings or structures more than six stories in height, occupant notification also shall be provided by an approved means of voice notification. K. In all new apartment buildings and structures, a total automatic fire detection system is required. Approved single station or multiple station smoke detectors continuously powered by house electrical service shall be installed in every living unit within the apartment building, regardless of the number or stories or number of apartments. This individual detector unit shall be in addition to any sprinkler system or other detection system that may be installed in the building. L. In all new apartment occupancies automatic sprinklers shall be provided. The approved automatic sprinklers shall be installed in corridors along the corridor ceiling, one sprinkler head opposite the center of any inside door of a living unit opening into the corridor. Automatic sprinklers shall be provided in each habitable apartment or living unit. The type of sprinkler head(s) used inside each habitable unit shall be of the quick-response type. Sprinklers in dwelling units may be omitted in small areas such as closets not over 24 square feet and bathrooms not over 60 square feet. M. The fire protection rating of doors from living units to corridors shall not be less than 20 minutes. All doors between apartments and corridors shall be self-closing. N. Portable fire extinguishers shall be provided in all corridors and hazardous areas. O. All new apartment buildings and apartment occupancies shall conform to this code and the Life Safety Code of NFPA.
Ask a question about Harrisburg law
Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.
