§ 3-903.21 — Operating features
Code of the City of Harrisburg, Pennsylvania · Harrisburg Code § 3-903.21
Corpus is an independent public-information project, not the official City of Harrisburg website. Stable reference: corpuslaw.us/code/a865a03f-d2d9-41f7-b5b2-aea7b5e854d3
§ 3-903.21: Operating features.
A. Every required exit, exit access or exit discharge shall be continuously maintained free of all obstructions or impediments to fully, instantly be available for use in the case of fire or other emergency. B. Hangings or draperies shall not be placed over exit doors or otherwise located so as to conceal or obscure any exit. No mirror shall be placed on an exit door or adjacent to any exit. C. There shall be no obstruction by railings, barriers or gates that divides the open space in sections appurtenant to individual rooms, apartments, means of egress, exits, or other uses. D. Every required automatic sprinkler system, fire detection and alarm system, smoke control system, exit lighting, fire door(s), and other items of equipment required by this code shall be continuously in proper operating condition. E. A functional test shall be conducted on every required emergency lighting system at thirty-day intervals. An annual test shall be conducted of smoke control systems, standpipe systems, sprinkler systems, and other equipment as required by this code. If any system is down for maintenance or repair, a test must be made after work is completed. F. Furnishings or decorations of an explosive or highly flammable character shall not be used. G. Fire-retardant coatings shall be maintained so as to retain the effectiveness of the treatment under conditions encountered in use. H. Fire exit drills shall be designed to familiarize the occupants with all available means of exit, particularly emergency exits that are not habitually used for normal egress of the building. Staff personnel should have instruction on fire exits and must participate in fire exit drills. I. No person shall smoke in prohibited areas which are so posted. J. Seats not secured to the floor may be permitted in restaurants, nightclubs and other occupancies where the fastening of seats to the floor may be impracticable, provided that, in the area used for seating (excluding dance floor stage, etc.), there shall be not more than one seat for each 15 square feet of net floor area, and adequate aisles to reach exits shall be maintained at all times. K. Every room constituting an assembly occupancy and not having fixed seats shall have the occupant load of the room posted in a conspicuous place near the main exit from the room. Signs shall be durable and indicate the number of persons permitted for each room use. L. There shall be at least two fire exit drills the first two weeks of a school term and eight additional fire exit drills during a school year. In climates where the winter weather is severe, at least six drills a year shall be held at the beginning of the school term and four drills after the winter months to complete the 10 required fire drills. The principal of each school shall maintain a record of the fire exit drills for inspection by the Fire Chief. M. Fire prevention inspections shall be conducted monthly by a trained senior member of the staff of all day-care facilities. This is not intended to eliminate inspections by members of the Fire Bureau. A record of such inspections by the staff member shall be maintained and readily available for inspection by the Fire Chief. N. The administration of every hospital, nursing home and custodial care facility shall have in effect and available to all supervisory personnel written copies of a plan for the protection of all persons in the event of fire for their evacuation to areas of refuge and from the building when necessary. All employees shall be periodically instructed and kept informed as to their duties under the plan. A copy of the plan shall be readily available at all times at the telephone operator's position and at the security center. O. All employees of hotels shall be instructed and drilled in the duties they are to perform in the event of fire, panic, or other emergency. Emergency duties of employees of residential occupancies shall be the following: notify the Fire Bureau, notify the office, warn guests, assist occupants, search rooms, man all elevators (including automatic-type elevators), and have a messenger to meet the Fire Bureau to give specific information and location of the emergency. P. Firesafety information shall be posted in every guest room of any type of residential occupancy such as hotels, motels, and dormitories. Q. The administration of every residential board and care facility shall have in effect and available to all supervisory personnel written copies of a plan for the protection of all persons in the event of fire and for the evacuation from the building when necessary to areas of refuge. The plan shall include special staff actions, including fire protection procedures needed to ensure the safety of any resident. All employees shall be periodically instructed and kept informed in respect to their duties and responsibilities. R. Fire exit drills in board and care homes and facilities shall be conducted at least six times per year, two times on each shift. A record shall be maintained of these drills and be available for inspection by the Fire Chief.
Ask a question about Harrisburg law
Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.