For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3-903.7 — Existing health care occupancies

Code of the City of Harrisburg, Pennsylvania · Harrisburg Code § 3-903.7

Corpus is an independent public-information project, not the official City of Harrisburg website. Stable reference: corpuslaw.us/code/13af9a7d-21bc-40a8-a9d3-7cf6e056feb6

§ 3-903.7: Existing health care occupancies.

A. Existing health care occupancies are those used for medical or other treatments or care of four or more persons suffering from physical or mental illness, disease or infirmity and for the care of infants, convalescents or infirm aged persons. Existing health care occupancies provide sleeping accommodations for the occupants and are occupied by persons who are mostly incapable of self-preservation because of age, physical or mental disability, or because of security measures not under the occupants' control. B. This section relating to existing health care occupancies is to be applied retroactively. The specified provisions, viewed as a whole, establish minimum acceptable criteria for life safety which reasonably minimize the likelihood of a life-threatening fire. C. Existing health care occupancies shall be so designed, constructed, maintained, and operated as to minimize the possibility of a fire emergency requiring the evacuation of occupants. D. A conversion from a hospital to a nursing home or from a nursing home to a hospital is not considered a change in occupancy classification. E. During any construction or alterations of an existing health care facility, care should be taken to prevent any blocking of means of egress for the existing building by the construction of such barriers. It is necessary to ensure that all extinguishing equipment for fire protection and all portions of the required means of egress are maintained in full working order. F. The requirements of this section may be modified if their application clearly would be impractical in the judgment of the authority having jurisdiction if the resulting arrangement could be considered as presenting a minimum hazard to the life safety of the occupants. G. The Fire Chief and the owner of the facility shall jointly develop a schedule for the correction of various deficiencies. H. The occupant load for existing health care facilities for which means of egress shall be provided for any floor shall be the maximum number of persons intended to occupy that floor as follows: (1) One person for each 120 square feet gross floor area in health care sleeping departments. (2) One person for each 240 square feet gross floor area of inpatient health care treatment departments. I. Every aisle, passageway, corridor, exit discharge, exit location, and access shall be in accordance with Chapter 5 of the Life Safety Code of NFPA. Aisles, corridors and ramps required for exit access in a hospital or nursing home shall be at least eight feet in clear and unobstructed width. J. The capacity of means of egress providing travel by means of stairs shall be 22 persons per unit, and the capacity of means of egress providing horizontal travel (without stairs), such as ramps, doors or horizontal exits, shall be 30 persons per unit. If the existing health care facility is automatically sprinkled, the stair exit may be increased to 35 persons per unit and the horizontal travel may be increased to 45 persons per unit. K. At least one exit from each floor or fire section shall be either: (1) A door leading directly to the outside of the building; (2) A stairway; (3) A smoke-proof enclosure; (4) A ramp; or (5) An exit passageway. L. All required exit ramps or stairs shall discharge directly to the outside at grade or be arranged to travel through an exit stairway discharging to the outside at grade. M. For all existing health care facilities means of egress shall be marked. N. All existing health care facilities shall have adequate illumination of exits. Illumination of means of egress shall be continuous during the time that the conditions of occupancy require availability of the means of egress. O. The floors of means of egress shall be illuminated at all angles and points of corridors and passageways, ramps, stairways, landing of stairs, stoops, and exit doors. P. All existing health care facilities shall be provided with emergency lighting. Lighting systems shall be so arranged as to provide the required illumination automatically in the event of any interruption of normal lighting, such as a power failure of a public utility or other outside power source, opening of a circuit breaker or fuse, or any manual act(s). The emergency lighting shall be provided in the following areas: (1) In all interior stairs, ramps and corridors; (2) In normally occupied areas; and (3) In all portions of buildings that are interior or windowless. Q. Locks shall not be permitted on patient sleeping room doors. In buildings in which other doors are locked, provision shall be made for the rapid removal of occupants by such reliable means as the remote control of locks or by keying all locks to keys readily available to staff who are in constant attendance. R. Any hazardous area shall be safeguarded by a fire barrier of a one-hour fire-resistance rating and/or provided with an automatic fire extinguishing system. Hazardous areas in existing health care facilities include but are not restricted to the following: (1) Boiler and heater rooms; (2) Laundries; (3) Repair or paint shops; (4) Handicraft shops; (5) Employee locker rooms; (6) Soiled linen rooms; (7) Trash collection rooms; (8) Rooms or spaces, including repair shops, used for storage of combustible supplies and equipment in the quantities deemed hazardous by the authority having jurisdiction; and (9) Laboratories employing quantities of flammable or combustible materials less than that which would be considered severe. S. The hazard level of a laboratory is considered severe if quantities of flammable, combustible or hazardous materials are present which are capable of sustaining a fire condition of sufficient magnitude to breach a one-hour fire separation partition. T. All existing health care occupancies shall be provided with an approved fire alarm system. U. All existing health care facilities shall have an approved automatic smoke detection system installed in all corridors of nursing homes, custodial care and supervisory care facilities. V. All existing health care occupancies shall be protected with automatic sprinklers. All existing health care facilities shall provide automatic sprinkler protection in all habitable patient care rooms. The sprinkler heads in the patient rooms shall be of the fast-response type head. Automatic sprinkler protection is required in any case where combustible elements are used in the construction or alteration of a health care facility. All health care facilities having floor level more than 75 feet above the level of the Fire Bureau access must be protected with automatic sprinklers. All existing health care facilities shall have five years from the effective date of this chapter to comply with the requirements in this subsection. W. Every patient sleeping room shall have a window or door to the outdoors arranged and located so that it can be opened from the inside to permit venting of products of combustion and to permit any occupant to have direct access to fresh air in case of emergency. Exceptions are: (1) Areas housing ICU, CCU, hemodialysis, and neonatal patients; (2) Rooms intended for occupancy of less than 24 hours, labor rooms, recovery rooms, and observation areas in emergency departments and newborn nurseries; and (3) Buildings designed with approved engineered smoke control systems. X. No portable space heating devices shall be permitted in any existing health care facility. Y. No smoking shall be permitted in any patient areas of any health care facility. Only in those areas approved by the Fire Chief will smoking be permitted. Z. All existing health care occupancies shall conform to Section 13-1 of the Life Safety Code of NFPA.

Ask a question about Harrisburg law

Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.