§ 3-903.8 — New hotels and dormitories
Code of the City of Harrisburg, Pennsylvania · Harrisburg Code § 3-903.8
Corpus is an independent public-information project, not the official City of Harrisburg website. Stable reference: corpuslaw.us/code/0998711b-214b-4d4e-8983-c7dde9d104f1
§ 3-903.8: New hotels and dormitories.
A. This section establishes life safety requirements for all new hotels and dormitories and alteration thereof. All new dormitories shall comply with the requirements for new hotels. Any rooming house or lodging house which contains more than 16 persons is considered a hotel and must comply with this section and Section 16-1 of the Life Safety Code of NFPA. B. The occupant load shall be determined on the basis of one person per 200 square feet gross floor area or the maximum probable population of any room or section under consideration, whichever is greater. C. Dormitory-type occupancy, particularly where two- or three-tier bunks are used with close spacing, may produce an occupant load substantially greater than one person per 200 square feet gross floor area. However, even though sleeping areas are densely populated, the building as a whole may not exceed one person per 200 square feet gross area. D. Not fewer than two exits shall be accessible from every floor, including floors below the level of exit discharge and occupied for public purposes. Exits shall be so arranged that, from any door opening to a corridor, exits will be accessible in at least two different directions. E. At least half of the required number of units of exit width from upper floors, exclusive of horizontal exits, shall lead directly to the street or through a yard, court, or passageway with protected openings and separated from all parts of the interior of the building. F. All means of egress and exits shall be illuminated. Illumination of means of egress shall be continuous during the time that the conditions of occupancy require the availability of the means of egress. G. The floors of means of egress shall be illuminated at all angles and points of corridors and passageways, stairways, landing of stairs and exit doors. H. All means of egress shall be marked. No door in any means of egress shall be locked against the egress when the building is occupied. Locks, if provided, shall not require the use of a key, tool, or special knowledge or effort for operation from the inside of the building. Ordinary double-cylinder locks or chain locks do not meet the provisions of this section. I. A fire alarm system in accordance with Section 7-6 of the Life Safety Code of NFPA is required. J. Each sleeping area and room shall be provided with an approved single station smoke detector powered from the building electrical source. K. All new hotels and dormitories shall be provided with an approved automatic sprinkler system in accordance with the requirements of NFPA 13, except that sprinklers may be deleted from closets within guests rooms of less than 24 square feet and from bathrooms within guest rooms less than 60 square feet in size. All guest rooms with sprinkler installation shall be fitted with a quick-response sprinkler head(s). L. Portable fire extinguishers shall be provided in all areas that are considered hazardous and on each floor as per the square footage of the corridors and the occupancies of each floor. M. Each guest room shall be provided with at least one window to the outdoors. Such windows shall be operable from the inside, without the use of tools, and provide a clear opening of not less than 20 inches in width and 24 inches in height. Windows may serve as a means of emergency escape. N. In buildings greater than six stories, at least one elevator shall be provided with a protected power supply and be available for use by the Fire Bureau in case of an emergency. O. All new hotels and dormitories shall conform to Section 16-1 of the Life Safety Code of NFPA.
Ask a question about Harrisburg law
Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.