§ 3-903.9 — Existing hotels and dormitories
Code of the City of Harrisburg, Pennsylvania · Harrisburg Code § 3-903.9
Corpus is an independent public-information project, not the official City of Harrisburg website. Stable reference: corpuslaw.us/code/8b76a291-725d-48b3-a465-0ce4bed21630
§ 3-903.9: Existing hotels and dormitories.
A. This section establishes life safety requirements for existing hotels and dormitories. Any rooming house or lodging house which contains more than 16 persons is considered a hotel and must comply with Section 17-1 of the Life Safety Code of NFPA and this section. B. The occupant load shall be determined on the basis of one person per 200 square feet gross floor area or the maximum probable population of any room or section under consideration, whichever is greater. C. Existing dormitory-type occupancy, particularly where two- or three-tier bunks are used with close spacing, may produce an occupant load substantially greater than one person per 200 square feet gross floor area. However, even though sleeping areas are densely populated, the building as a whole may not exceed one person per 200 square feet gross area. D. Not fewer than two exits shall be accessible from every floor, including floors below the level of exit discharge and occupied for public purposes. Exits shall be so arranged that, from any door opening to a corridor, exits will be accessible in at least two different directions. E. At least half of the required number of units of exit width from upper floors, exclusive of horizontal exits, shall lead directly to the street or through a yard, court, or passageway with protected openings and separated from all parts of the interior of the building. F. All means of egress and exits shall be illuminated. Illumination of means of egress shall be continuous during the time that the conditions of occupancy require the availability of means of egress. G. The floors of means of egress shall be illuminated at all angles and points of corridors and passageways, stairways, landings of stairs and exit doors. H. All means of egress shall be marked. No door in any means of egress shall be locked against egress when the building is occupied. Locks, if provided, shall not require the use of a key, tool, or special knowledge or effort for operation from the inside of the building. Ordinary double-cylinder locks and chain locks do not meet the provisions of this section. I. A fire alarm system in accordance with Section 7-6 of the Life Safety Code of NFPA shall be installed in each existing hotel and dormitory. J. Each sleeping area and room shall be provided with an approved single station smoke detector powered from the building electrical source. K. All existing hotels and dormitories shall be provided with emergency lighting. Emergency lighting systems shall be so arranged as to provide the required illumination automatically in the event of any interruption of normal lighting, such as a power failure of a public utility or other outside power source, opening of a circuit breaker or fuse, or any manual act(s). L. All existing hotels and dormitories shall be provided with an approved automatic sprinkler system in accordance with the requirements of NFPA 13. All habitable guest rooms shall be provided with automatic sprinklers. The sprinkler head(s) in guest rooms shall be of the quick-response type. Sprinklers are not required in closets within guest rooms of less than 24 square feet and in bathrooms in guest rooms less than 60 square feet in size. All existing hotels and dormitories shall have five years from the effective date of this code to meet the requirements of this particular subsection. M. Portable fire extinguishers shall be provided in all areas that are considered hazardous. N. Any transoms in any existing hotel or dormitory shall be fixed in the closed position and shall be covered or otherwise protected to provide a fire-resistance rating. O. All guest room doors shall be provided with a self-closing device. All doors in corridors shall be provided with a self-closing device. All existing hotels and dormitories shall have one year from the effective date of this code to meet the requirements of this particular subsection. P. All existing hotels and dormitories shall conform to Section 17-1 of the Life Safety Code of NFPA.
Ask a question about Harrisburg law
Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.