For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3-903.6 — New health care occupancies

Code of the City of Harrisburg, Pennsylvania · Harrisburg Code § 3-903.6

Corpus is an independent public-information project, not the official City of Harrisburg website. Stable reference: corpuslaw.us/code/52c7ab81-69b4-4984-9160-5087f7f2a932

§ 3-903.6: New health care occupancies.

A. Health care occupancies are those used for medical or other treatments or care of four or more persons suffering from physical or mental illness, disease or infirmity and for the care of infants, convalescents or infirm aged persons. Health care facilities provide sleeping accommodations for the occupants and are occupied by persons who are mostly incapable of self-preservation because of age, physical or mental disability or because of security measures not under the occupants' control. B. The objective of this section is to provide a reasonable level of safety by reducing the probability of injury and loss of life from the effects of fire. This objective is accomplished in the context of the physical facilities, the provisions for the capabilities of the staff, and the needs of all occupants through the requirements directed at the following: (1) Prevention of ignition; (2) Detection of the fire; (3) Control of fire development; (4) Confinement of the effects of fire; (5) Extinguishment of the fire; (6) Provision of refuge and/or evacuation facilities; and (7) Staff reaction. C. New health care occupancies in buildings housing other occupancies shall be completely separated from them by construction having a fire-resistance rating of at least two hours. D. The occupant load for which means of egress shall be provided for any floor shall be the maximum number of persons intended to occupy that floor: (1) One person for each 120 square feet of gross floor area in health care sleeping departments; and (2) One person for each 240 square feet of the gross floor area of inpatient health care treatment departments. E. Every aisle, passageway, corridor, exit discharge, exit location and access shall be in accordance with Chapter 5 of the Life Safety Code of NFPA. Aisles, corridors and ramps required for exit access in a hospital or nursing home shall be at least eight feet in clear and unobstructed width. F. The capacity of means of egress providing travel by means of stairs shall be 22 persons per exit unit, and the capacity of means of egress providing horizontal travel without stairs, such as ramps, doors, or horizontal exits, shall be 30 persons per unit. G. Health care occupancies are the only occupancies in the code that allow an increase in exit capacity due to automatic sprinkler protection. If a health care facility is totally equipped with a sprinkler system, the stair exit may be increased to 35 persons per unit and the horizontal level may be increased to 45 persons per unit. H. At least one exit from each floor or fire section shall be either: (1) A door leading directly to the outside of the building; (2) A stair; (3) A smoke-proof enclosure; (4) A ramp; or (5) An exit passageway. I. All required exit ramps or stairs shall discharge directly to the outside at grade or be arranged to travel through an exit passageway discharging to the outside at grade. J. For all new health care occupancies, the means of egress shall be marked (signed). K. All new health care facilities shall have adequate illumination of exits. Illumination of means of egress shall be continuous during the time that the conditions of occupancy require that the means of egress be available for use. L. The floors of means of egress shall be illuminated at all angles and points of corridors and passageways, ramps, stairways, landing of stairs, stoops and exit doors. M. All new health care facilities shall be provided with emergency lighting. Emergency lighting systems shall be so arranged as to provide the required illumination automatically in the event of any interruption of normal lighting, such as a power failure of a public utility or other outside power source, opening of a circuit breaker or fuse, or manual act(s). The emergency lighting shall be provided in the following areas: (1) In all interior stairs, ramps and corridors. (2) In normally occupied areas. (3) In all portions of buildings that are interior or windowless. N. Locks shall not be permitted on patient sleeping room doors. O. In buildings in which doors are locked, provisions shall be made for the rapid removal of occupants by such reliable means as the remote control of locks or by keying all locks to keys readily available to staff who are in constant attendance. P. In new health care occupancies, any hazardous area shall be either safeguarded by a fire barrier of one-hour fire-resistance rating or provided with an automatic fire extinguishing system. Those areas accompanied by an asterisk (*) in the list below shall have both fire-resistant separation and a complete extinguishment system, but the list is not intended to be all-inclusive: (1) Boiler and heater rooms; (2) Laundries; (3) Repair shops; (4) Handicraft shops; (5) Employee locker rooms; (6) Soiled linen rooms;* (7) Paint shops;* (8) Trash collection rooms;* (9) Rooms or spaces, including repair shops, used for the storage of combustible supplies and equipment in quantities deemed hazardous by the authority having jurisdiction; and* (10) Laboratories employing quantities of flammable or combustible materials less than that which would be considered severe. Q. Laboratories employing quantities of flammable, combustible, or hazardous materials which are considered as severe hazards shall be protected in accordance with NFPA 99. R. All new health care occupancies shall be provided with an approved fire alarm system. S. All new health care occupancies shall have an approved automatic smoke detection system installed in all corridors, nursing homes, custodial care, and supervisory care facilities. In no case shall smoke detectors be spaced further apart than 30 feet on center or more than 15 feet from any wall. T. All new health care occupancies shall be protected with automatic sprinklers. Automatic sprinklers shall be provided in each habitable patient room. The sprinkler head(s) in each patient room shall be the quick-response type head. Automatic sprinkler protection is required in any area where combustible elements are used in the construction of a health care facility. Additionally, because of the inherent risks associated with tall buildings and because of the difficulties encountered in manually firefighting in such structures, all health care facilities having floor levels more than 75 feet above the level of Fire Bureau access must be protected with automatic sprinklers. U. Every patient sleeping room shall have a window or door to the outdoors arranged and located so that it can be opened from the inside to permit venting of products of combustion and to permit any occupant to have direct fresh air in case of emergency. Exceptions: (1) Areas housing ICU, CCU, hemodialysis, and neonatal patients; (2) Rooms intended for occupancy of less than 24 hours, labor rooms, recovery rooms, and observation areas in emergency departments and newborn nurseries; and (3) Buildings designed with approved engineered smoke control systems. V. No portable space heating devices shall be permitted in any new health care occupancy. W. No smoking shall be permitted in any patient areas of any new health care facility. Only in those areas approved by the Fire Chief will smoking be permitted. X. All new health care occupancies shall conform to Section 12-1 of the Life Safety Code of NFPA.

Ask a question about Harrisburg law

Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.