§ 3-903.5 — Existing educational occupancies
Code of the City of Harrisburg, Pennsylvania · Harrisburg Code § 3-903.5
Corpus is an independent public-information project, not the official City of Harrisburg website. Stable reference: corpuslaw.us/code/36bb9d87-412e-4a48-bda5-7ac3aaea390c
§ 3-903.5: Existing educational occupancies.
A. Existing educational occupancies shall include all buildings and structures used for the gathering of groups of six or more persons for the purposes of instruction for four or more hours per day or more than 12 hours per week. B. Rooms normally occupied by preschool, kindergarten, or first-grade pupils shall not be located above or below the level of exit discharge. Rooms normally occupied by second-grade pupils shall not be located more than one story above the level of exit discharge. C. Existing educational occupancies housing classes over the 12th grade shall comply with the following classification requirements: (1) Instructional building: business occupancy. (2) Classrooms under 50 persons: business occupancy. (3) Classrooms 50 persons and over: assembly occupancy. (4) Laboratories, instructional: business occupancy. (5) Laboratories, noninstructional: industrial. D. Educational occupancies shall include all buildings used for educational purposes. Educational occupancies for students of high school age and below are distinguished from assembly occupancies since the same occupants are regularly present and they are subject to discipline and control. Sunday schools or church schools which are not used for daily classes throughout the week are considered to fall within the scope of assembly occupancies. E. Existing educational occupancies include day-care facilities, nursery schools, kindergartens and other schools whose purpose is primarily educational even though the children are of preschool age.[1] F. The occupant load of existing educational occupancies, buildings and structures or any individual story or section thereof for the purpose of determining exits shall be as follows: (1) One person for each 20 square feet of net classroom area. (2) One person for each 50 square feet of net area of shops, laboratories, and similar vocational rooms. (3) One person for each 35 square feet in day-care centers. G. All means of egress in existing educational facilities shall be in accordance with Chapter 5 of the Life Safety Code of NFPA. H. All exit corridors of existing educational facilities shall not be less than six feet wide. I. In all existing educational facilities there shall be at least two exits available from every floor. J. All exits shall be arranged so that at least two separate exits will be available from every floor area. Exits shall be as remote as practicable from each other, so arranged that there will not be pockets or dead ends in which occupants may be trapped, and in no case shall any dead-end corridor extend more than 20 feet beyond the stairway of other means of exit therefrom. K. Every room or space with a capacity of more than 50 persons or more than 1,000 square feet in area shall have at least two doorways as remote from each other as practicable. Such doorways shall provide access to separate exits and may open upon a common corridor. L. All existing educational buildings and structures shall have adequate illumination of exits. Illumination of means of egress shall be continuous during the time that the conditions of occupancy require availability of the means of egress. M. The floors of means of egress shall be illuminated at all points of corridors and passageways, stairways, landings of stairs, stoops, and exit doors. N. All existing educational facilities shall have emergency lighting. Emergency lighting systems shall be so arranged as to provide the required illumination automatically in the event of any interruption of normal lighting, such as power failure of a public utility or other outside power source, opening of a circuit breaker or fuse, or any manual act(s). The emergency lighting shall be provided in the following areas: (1) In all interior stairs and corridors; (2) In normally occupied spaces; (3) In flexible or open buildings (open plan type); and (4) In all portions of buildings that are interior or windowless. O. In all existing educational occupancies, all means of egress shall be marked. P. Any door in a required means of egress from an area having an occupant load of 100 or more persons may be provided with a latch or lock only if it is panic hardware or fire exit hardware. Q. Every room or space used for classroom or other educational purposes or normally subject to student activity or occupancy shall have at least one window to the outdoors used for emergency rescue or ventilation. Such window shall be opened from the inside without the use of tools and provide a clear opening of not less than 20 inches in width and 24 inches in height. R. Janitor closets shall be protected by an automatic sprinkler system which may be supplied by the domestic water supply serving no more than six sprinklers and having a water supply sufficient to provide 0.15 gpm of floor area. S. In existing educational occupancies with automatic sprinkler protection, the operation of the sprinkler system shall automatically activate the fire alarm system. T. All existing educational occupancies shall be provided with a fire alarm system in accordance with Section 7-6 of the Life Safety Code of NFPA. U. Every portion of existing educational buildings or structures below the floor of exit discharge shall be provided throughout with an approved automatic sprinkler system. V. All existing educational occupancies shall conform to Section 11-1 of the Life Safety Code of NFPA.
Ask a question about Harrisburg law
Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.