§ 3-903.4 — New educational occupancies
Code of the City of Harrisburg, Pennsylvania · Harrisburg Code § 3-903.4
Corpus is an independent public-information project, not the official City of Harrisburg website. Stable reference: corpuslaw.us/code/c51c503a-4bb7-4cb5-8b98-467428d4637c
§ 3-903.4: New educational occupancies.
A. Educational occupancies shall include all buildings used for the gathering of groups of six or more people for the purpose of instruction for four or more hours per day or more than 12 hours per week. B. Rooms normally occupied by preschool, kindergarten, or first-grade pupils shall not be located above or below the level of exit discharge. Rooms normally occupied by second-grade pupils shall not be located more than one story above the level of exit discharge. C. Educational occupancies housing classes over the 12th grade shall comply with the following classification requirements: (1) Instructional building: business occupancy. (2) Classrooms under 50 persons: business occupancy. (3) Classrooms 50 persons and over: assembly occupancy. (4) Laboratories, instructional: business occupancy. (5) Laboratories, noninstructional: industrial. D. The occupant load of new educational buildings or any individual story thereof, or any portion thereof, for the purpose of determining exits, shall be as follows: (1) One person for each 20 square feet of net classroom area. (2) One person per 50 square feet of net area of shops, laboratories, and similar vocational rooms. (3) One person per 35 square feet of net area of day-care institutions and child-care facilities. E. All means of egress shall be in accordance with Chapter 5 of the Life Safety Code of NFPA. F. Exit access corridors shall not be less than six feet wide. G. In all new educational occupancies there shall be at least two exits available from every floor area. H. Exits shall be arranged so that at least two separate exits will be available from every floor area. Exits shall be as remote from each other as possible, so arranged that there will not be pockets or dead ends in which occupants could become trapped, and in no case shall any dead-end corridor extend more than 20 feet beyond the stairway of other means of exit therefrom. I. All new educational buildings or structures shall have adequate illumination of exits. Illumination of means of egress shall be continuous for the time that conditions of occupancy require availability of the means of egress. J. The floors of means of egress shall be illuminated at all points of corridors and passageways, stairways, landings of stairs, stoops, and exit doors. K. All new educational occupancies shall have emergency lighting. Emergency lighting systems shall be so arranged as to provide the required illumination automatically in the event of any interruption of normal lighting, such as a power failure of a public utility, other outside power source, opening of a circuit breaker or fuse, or any manual act(s). The emergency lighting shall be provided in the following areas: (1) In all interior stairs and corridors; (2) In all normally occupied spaces; (3) In flexible or open buildings (open plan type); and (4) In all portions of buildings that are interior or windowless. L. In all new educational occupancies all means of egress shall be marked. M. Any door in a required means of egress from an area having an occupant load of 100 or more persons may be provided with a latch or lock only if it is panic hardware or fire exit hardware. N. Every room or space used for classroom or other educational purposes or normally subject to student activity or occupancy shall have at least one window to the outdoors used for emergency rescue or ventilation. Such window shall be openable from the inside without the use of tools and provide a clear opening of not less than 20 inches in width and 24 inches in height. O. Janitor closets shall be protected by an automatic sprinkler system, which may be supplied by the domestic water supply, serving no more than six sprinklers and having a water supply sufficient to provide 0.15 gpm of the floor area. P. All new educational occupancies shall be provided with a fire alarm system in accordance with Section 7-6 of the Life Safety Code of NFPA. Q. In new educational occupancies provided with automatic sprinkler protection, the operation of the sprinkler system shall automatically activate the fire alarm system. R. Every portion of new educational buildings or structures below the floor of exit discharge shall be provided and protected throughout by an approved automatic sprinkler system. S. All new educational occupancies shall conform to Section 10-1 of the Life Safety Code of NFPA.
Ask a question about Harrisburg law
Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.
