§ 3-903.11 — Existing apartment buildings
Code of the City of Harrisburg, Pennsylvania · Harrisburg Code § 3-903.11
Corpus is an independent public-information project, not the official City of Harrisburg website. Stable reference: corpuslaw.us/code/780f1e7b-2dc5-4ef4-9599-b5dbe62a6170
§ 3-903.11: Existing apartment buildings.
This section establishes life safety requirements for all existing apartment buildings and structures housing apartments. This includes buildings or structures containing three or more dwelling units with independent cooking and bathroom facilities, whether designated as apartment house, tenement, garden apartment, townhouse, condominium, or by any other name. A. All existing buildings or structures classified as apartment occupancies shall conform to the provisions of the Life Safety Code of NFPA, Section 19-1, and shall meet the requirements of one of the following options: (1) Buildings provided with a complete automatic fire detection and notification system. (2) Buildings provided with automatic sprinkler protection in selected areas. (3) Buildings protected throughout by an approved automatic sprinkler system. B. Each dwelling unit in an existing apartment house shall have at least one single station smoke detector. C. No required path of travel to the outside from any room used as a means of escape shall be through another room or apartment not under the immediate control of the occupants of the first room, nor through a bathroom or other space subject to locking. D. Every dwelling unit in existing apartment occupancies shall have access to at least two separate exits remote from each other. E. Every public space, hallway, stairway, and other means of egress shall have illumination which shall be continuous. F. The floors of means of egress shall be illuminated at all angles and points of corridors and passageways, stairways, landings of stairs, and exit doors. G. Any apartment building with more than three living units or greater than three stories in height shall have emergency lighting. The emergency lighting systems shall be so arranged as to provide the required illumination automatically in the event of any interruption of normal lighting, such as a power failure of a public utility or other power source, opening of a circuit breaker or fuse, or any manual act(s). H. All means of egress shall be marked. Exit signs shall be posted in all apartment buildings requiring more than one exit. I. No door in any means of egress shall be locked against egress when the building is occupied. Locks, if provided, shall not require the use of a key, tool, or special knowledge or effort for operation from the inside of the building. Ordinary double-cylinder locks or chain locks do not meet the provisions of this section. J. Approved interconnected smoke detectors continuously powered by the house electrical service shall be installed in all common areas such as basements, cellars, hallways, corridors, or landings within the apartment building regardless of the number of stories. The individual unit detectors shall be in addition to any sprinkler system or other detection system that may be installed in the building. K. All existing apartment occupancies over 75 feet in height shall be provided with an automatic sprinkler system in all corridors and in all habitable rooms or living units. A quick-response sprinkler head(s) shall be installed as part of the automatic sprinkler system in all habitable areas or living units throughout. Sprinklers may be omitted in small areas, such as closets not over 24 square feet and bathrooms not over 60 square feet. For existing apartment occupancies to meet the requirements of this subsection, a five-year period from the effective date of this code shall be given to comply. L. The fire protection rating of fire doors from dwelling units opening onto corridors shall be not less than 20 minutes. Doors between dwelling units and corridors shall be self-closing. Doors shall be equipped with latches for keeping doors closed. M. Existing transoms installed in corridor partitions of sleeping rooms shall be fixed in the closed position and shall be covered or otherwise protected to provide a fire-resistance rating. N. Portable fire extinguishers shall be provided in all corridors and hazardous areas. O. Apartment buildings with more than three stories or with more than 11 dwelling units shall be provided with a fire alarm system in accordance with Section 7-6 of the Life Safety Code 101.
Ask a question about Harrisburg law
Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.