§ 3-903.13 — Residential board and care occupancies
Code of the City of Harrisburg, Pennsylvania · Harrisburg Code § 3-903.13
Corpus is an independent public-information project, not the official City of Harrisburg website. Stable reference: corpuslaw.us/code/7e1de474-ee72-4d44-accc-fffcbc582d90
§ 3-903.13: Residential board and care occupancies.
A. This section addresses the life safety of those persons in residential board and care occupancies. The following are examples of facilities that may be classified as residential board and care services: (1) A group housing arrangement for physically and mentally handicapped persons who normally may attend school in the community, attend church in the community, or otherwise use community services. (2) A group housing arrangement for physically or mentally handicapped persons who are undergoing training in preparation for independent living, for paid employment or other normal community services. (3) A group housing arrangement for the elderly that provides personal care services but that does not provide nursing care. (4) Facilities for social rehabilitation, alcoholism, drug abuse, or mental health problems that contain a group housing arrangement and that provide personal care services but do not provide acute care. (5) Other group housing arrangements that provide personal care services but not nursing care. B. Residential board and care occupancies providing sleeping accommodations for not more than 16 residents shall be classified as a small facility. An occupancy having more than 16 persons shall be classified as a large board and care facility. C. Each board and care occupancy shall have a type of evacuation capability permitting the occupants, residents and staff as a group to either evacuate the building or relocate from the point of occupancy to a point of safety. D. Any hazardous area shall be protected in accordance with the following: (1) If a hazardous area is on the same floor as, and is in or abuts, a primary means of escape or a sleeping room, the hazardous area shall be protected by either: (a) An enclosure with a fire-resistance rating of at least one hour with a self-closing fire door having a fire protection rating of at least 3/4 of an hour; or (b) Automatic sprinkler protection of the hazardous area and a separation that will resist the passage of smoke between the hazardous area and the exposed sleeping area. (2) Other hazardous areas shall be protected by either: (a) An enclosure with a fire-resistance rating of at least 20 minutes with a self-closing door at least the equivalent to a one-and-three-fourths-inch solid bonded wood core construction; or (b) Automatic sprinkler protection of the hazardous area regardless of enclosure. E. A manual fire alarm shall be provided in all board and care occupancies. Existing board and care occupancies shall have one year from the effective date of this code to comply with this requirement. F. In a large board and care occupancy, approved smoke detectors shall be installed. These shall be powered by the house electrical service and, when activated, shall initiate an alarm audible in the sleeping areas. Detectors shall be installed on all levels, including basements but excluding crawl spaces and attics. Additional detectors shall be installed for living rooms and day rooms. If the board and care occupancy is classified as small, a system of smoke detectors is required. Smoke detectors of a single station type must be installed on every level and in all habitable areas and halls or corridors and basement. G. All new board and care occupancies shall be provided throughout with an automatic sprinkler system installed in accordance with NFPA 13D, and such sprinkler system shall activate the fire alarm system. Existing board and care occupancies shall be provided throughout with an automatic sprinkler system. This automatic sprinkler system shall activate the fire alarm system. The type of sprinkler head to be used shall be the quick-response type. A five-year period to comply with this subsection will be given for existing occupancies. H. Portable fire extinguishers shall be provided near hazardous areas and on each floor of occupancy. I. All means of egress or escape must be marked. Exit signs shall be posted in all board and care occupancies. J. All board and care occupancies shall have separation from sleeping rooms to corridors with a fire-resistance rating of not less than 20 minutes. Other common spaces and walls shall have a fire-resistance rating of not less than 20 minutes. There shall be no louvers, transfer grilles, operable transoms or other passages penetrating such walls except properly installed utility installations. K. All board and care occupancies shall conform to the Life Safety Code of NFPA, Section 21-1.
Ask a question about Harrisburg law
Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.