§ 3-903.18 — Existing business occupancies
Code of the City of Harrisburg, Pennsylvania · Harrisburg Code § 3-903.18
Corpus is an independent public-information project, not the official City of Harrisburg website. Stable reference: corpuslaw.us/code/af6b4b4e-0dea-44e8-9708-3180600b6921
§ 3-903.18: Existing business occupancies.
A. Existing business occupancies are those used for the transaction of business for the purpose of keeping records and accounts and similar purposes. Minor office occupancies incidental to operations in another occupancy are considered part of the predominating occupancy and are subject to the provisions of this code as they apply to the predominating occupancy. B. All existing business occupancies shall conform to Chapter 27 of the Life Safety Code of NFPA. C. Any additions or alterations to existing buildings of business occupancies shall conform to the requirements for new construction. Existing portions of the structure need not be modified, provided that the new construction has not diminished the firesafety features of the facility. D. The following constitute business occupancies and are covered by Chapter 27 of the Life Safety Code of NFPA: (1) Those occupancies used for the transaction of business, other than those classified as mercantile occupancies. (2) Those occupancies used for the keeping of accounts and records and for similar purposes. (3) Doctors' offices, dentists' offices, general offices, city halls, and courthouses, all of which have areas for keeping books and records and transacting public business. (4) Service facilities usual to office buildings, such as newsstands, lunch counters (serving fewer than 50 persons), barbershops, beauty shops and gift shops. E. The occupant load of business occupancies in all buildings or parts of buildings used for business purposes shall be no less than one person per 100 square feet of gross floor area. F. No fewer than two exits shall be accessible from every part of every floor, including floor levels below the street floor occupied for business purposes or uses incidental thereto. G. Required exits must be suitably located to allow access without passage through areas subject to locking. H. All means of egress shall be illuminated. I. All means of egress shall be marked and signs posted. All exits shall be marked and all exits shall be posted with signs. J. Emergency lighting shall be required where: (1) The building is two or more stories in height above the level of exit discharge; (2) The occupancy is subject to 100 or more occupants above or below the level of exit discharge; (3) The occupancy is subject to 1,000 or more total occupants; or (4) A portion of the structure is windowless or underground. K. Locks shall be permitted only on principal entrance/exit doors which must be unlocked in order for the facility to do business when occupied. Locks shall not require the use of a key, tool, or special knowledge or effort for operation from the inside of the building. L. A door shall be so arranged as to be readily opened from the side from which egress is to be made at all times. M. Floors below the street level floor used for storage or other business occupancy shall have no unprotected opening to business occupancy floors. N. All existing business occupancies shall be provided with a fire alarm where: (1) The building is two or more stories in height above the level of exit discharge; (2) The occupancy is subject to 100 or more occupants above and/or below the level of exit discharge; or (3) The occupancy is subject to 1,000 or more total occupants. To conform to the requirements of this subsection of the Fire Code, a building owner(s) will have three years from the effective date of this code to comply with this requirement. O. All business occupancy buildings over 75 feet in height shall be protected throughout by an approved automatic sprinkler system, fully electrically supervised. Building height shall be measured from the lowest level of Fire Bureau access to the floor of the highest occupiable story. To conform to the requirements of this subsection of the Fire Code, a building owner(s) will have five years from the effective date of this code to comply with this requirement. P. All existing business occupancies with electrical equipment for smoke control or automatic extinguishing equipment for any building more than six stories in height or 75 feet in height containing an atrium shall be provided with an emergency source of power in accordance with NFPA 70. Q. All existing business occupancies housing atriums shall be protected with an automatic fire detection and fire alarm system. R. All existing business occupancies must be equipped throughout with portable fire extinguishers. In areas where micro or mini computer drive systems are located, these areas should be provided with halon extinguishers.
Ask a question about Harrisburg law
Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.